!
WA R N I N G
Do not insert a POL transport
plug (plastic part with external
threads) into the Type 1 tank
valve outlet. It will defeat the
Safety Relief Valve feature.
!
D A N G E R
Do not insert any tool or foreign
objects into the valve outlet or
safety relief valve. The valve may
be damaged resulting in a leak.
Leaking propane may result
in explosion, fire, severe
personal injury, or death.
If a leak is detected at any
time, STOP and call the
fire department.
If unable to stop a gas leak,
immediately close LP tank valve
and immediately contact an LP
gas supplier or fire department.
CONNECTING THE
REGULATOR TO THE
20LB. LP TANK
Leak test new and exchanged
LP tanks BEFORE connecting
to griddle. Please reference the
Leak Test Instructions section
.
01. LP tank must be properly
secured to griddle. (Refer to
assembly section.)
02. Turn all control knobs to the
OFF position.
03. Turn LP tank OFF by turning
OPD hand wheel clockwise to a
full stop.
04. Remove protective cap from LP
tank valve.
Section 02
CONNECTION & REMOVAL
05. Hold regulator and insert nipple
into LP tank valve.
06. Hand-tighten the coupling nut,
holding regulator in a straight
line (see figure below) with LP
tank valve so as not to cross
thread the connection.
Fuel | Propane – 20lb. Tank
!
WA R N I N G
Never attempt to attach
this griddle to the self-
contained LP gas system of
a camper trailer, recreational
vehicle or motor home.
Do not use the LP Tank until it
has been leak-tested.
07. Turn the coupling nut clock-
wise and tighten to a full stop.
The regulator will seal on the
back-check feature in the LP
tank valve, resulting in some
resistance.
08. An additional one-half to
three-quarters turn is required
to complete the connection.
Tighten by hand only – do not
use tools.
NOTE:
If connection cannot be
completed, disconnect regulator and
repeat steps 5 and 6.
If still unable to complete
connection, do not use this
regulator!
Call
435-252-3030 ext 1
for iden-
tical replacement parts.
20LB. LP TANK
REMOVAL FOR
TRANSPORT OR
STORAGE
01. Turn OFF all control knobs and
LP tank valve.
02. Turn coupling nut counter-
clockwise by hand only. Do not
use tools to disconnect.
03. Lift LP tank up and off of
support bracket.
04. Install safety cap onto LP
tank valve.
Always use cap and strap
supplied with valve.
Failure to use safety cap as directed
may result in serious personal injury
and/or property damage.
A disconnected LP tank in storage or
during transportation must have a
safety cap installed (as shown).
20lb. Tank – Propane | Fuel
| Owner’s Manual | Model 1858
21
Summary of Contents for PRO 1858
Page 25: ...20lb Tank Propane Fuel Owner s Manual Model 1858 23 ...
Page 32: ...North Atlantic Imports LLC 1073 West 1700 North Logan UT 84321 Blackstoneproducts com ...
Page 64: ...North Atlantic Imports LLC 1073 West 1700 North Logan UT 84321 Blackstoneproducts com ...
Page 96: ...North Atlantic Imports LLC 1073 West 1700 North Logan UT 84321 Blackstoneproducts com ...