F
E A T U R E S
Laundry Installation and Setup Guide
38
F
E A T U R E S
F
EATURES
• Includes 15-key keypad and an 8-line x 21 character LCD display
• Contains a keyed lock to secure the inside of the unit, along with a hinged door to access the circuit boards (
If
you prefer a high security lock or unique keys, you can purchase Medeco 60W-0750-239 from RA-LOCK
Company (800-777-6310.)
• Supports 10/100Base-T or RS-485 Communication
• Supports wired or 2.46Hz wireless communication to laundry machines
• Compatible with both Universal and Unix Editions of BbTS
Table 4: LC3000 Component Specifications
LC3000
Power
Input Voltage Range
Input Frequency
Input Current
120VAC
60Hz
1.4A, max
Operating Environment Temperature
Relative Humidity
Altitude
0 to +45C (+32 to +114F)
0 to 95 percent, non-condensing
0 -10,000 feet
Non-Operating
Environment
Temperature
Relative Humidity
Altitude
-20 to +70 C (-4 to +158F)
0 to 95 percent, non-condensing
0 - 35,000 feet
LE3/PSENCL
with LCM20
Power
Input Voltage Range
Input Frequency
Input Current
120VAC
60Hz
1.4A, max
Operating Environment Temperature
Relative Humidity
Altitude
0 to +45C (+32 to +114F)
0 to 95 percent, non-condensing
0 -10,000 feet
Non-Operating
Environment
Temperature
Relative Humidity
Altitude
-20 to +70 C (-4 to +158F)
0 to 95 percent, non-condensing
0 - 35,000 feet
LE3/BRIDGE
Power
Input Voltage Range
Input Frequency
Input Current
9 to 30 VAC or 7 to 36 VDC
60Hz
0.12A, max
Operating Environment Temperature
Relative Humidity
Altitude
0 to +45C (+32 to +114F)
0 to 95 percent, non-condensing
0 -10,000 feet
Non-Operating
Environment
Temperature
Relative Humidity
Altitude
-20 to +70 C (-4 to +158F)
0 to 95 percent, non-condensing
0 - 35,000 feet
LWI3xxx
Power
Input Voltage Range
Input Frequency
Input Current
9 to 30 VAC or 7 to 36 VDC
60Hz
0.12A, max
Operating Environment Temperature
Relative Humidity
Altitude
0 to +45C (+32 to +114F)
0 to 95 percent, non-condensing
0 -10,000 feet
Non-Operating
Environment
Temperature
Relative Humidity
Altitude
-20 to +70 C (-4 to +158F)
0 to 95 percent, non-condensing
0 - 35,000 feet