Laundry Installation and Setup Guide
20
L C I L
A U N D R Y
M
A C H I N E
I
N T E R F A C E
I
N S T A L L A T I O N
7
Terminate 4-conductor
cable at the LCM20, using
the 1 x 4 terminal block
provided in the hardware
kit.
Refer to
8
Replace laundry machine
operator console.
Figure 13: Maytag Stacked Machine
Depending on the labeling of upper and lower dryers and Maytag control board software version, pins may
need to be swapped to correctly match available signal with machine identifier.
Install Alliance/Speed Queen LCI3020 in Laundry Machine
The hardware kit includes a machine controller interface cable, splices and wire ties. Two LCI3020s must be
ordered when wiring to a stacked dryer.
1
Remove the operator
console (with display and
switches) from the machine.
Refer to the appropriate
Speed Queen service
manual.
2
Route the 4-conductor
cable from the LCM20 into
the machine (see
If the installation is for a
stacked machine, two
cables are required.
Figure 14: Alliance/Speed Queen Machine
BELDEN 8723 or equivalent
Cable to LCM20
6
5
4
3
2
1
1
2
3
4
LCM20
TBX
RED
BLK
WHT
RED
WHT
BLK
Laundry Machine
RED
WHT
BLK
2
1
1
2
3
4
LCM20
TBX
GRN
BLK
GR
N
Laundry Machine
BLK
GRN
1
2
BELDEN 8723 or equivalent
LCI 3020
Cable to LCM20
4
3
2
1
1
2
3
4
LCM20
TBX
RED
BLK
WHT
WHT
RED
BLK
Laundry Machine
WHT
RED
BLK