STAT-4, STAT-8, AND STAT-24
28
4. X-OFF Control Character Screen
Purpose:
View the character currently used to stop data transfer when using software flow control, and select
another character, if desired.
Description:
Code numbers 1 through 8 present the various characters that you can use as X-OFF control characters:
11H (DC1), 12H (DC2), 13H (DC3), 14H (DC4), 91H, 92H, 93H, or 94H. The current state line shows the
X-OFF character now in use.
Procedure:
To change the current selection, type the code number corresponding to the desired character: always check
that this character is different from the X-ON control character. To exit with or without change, type
Q
. You will
return to the System Configuration menu (2).
5. Modify Password Screen
Purpose:
Select a new password. The new password is activated after you verify it.
Description:
The screen prompts you to enter the new password (any two characters, except the characters serving as X-ON
and X-OFF flow-control characters), or exit to the System Configuration menu.
Procedure:
a. Type the desired password. You will receive the following message:
ENTER NEW PASSWORD AGAIN FOR VERIFICATION
b. Type the same characters again.
1. If the mux finds no difference between the passwords, it accepts the new password and you receive the
following message:
NEW PASSWORD HAS BEEN ACTIVATED ENTER ANOTHER PASSWORD (two characters)
OR PRESS Q TO EXIT
If you do not need to change the password again, press
Q
to return to the System Configuration menu.
Otherwise, repeat the password entry procedure.
2. If the two passwords differ, no change is made, and the following screen is presented:
INCORRECT VERIFICATION, PASSWORD HAS NOT BEEN CHANGED
ENTER NEW PASSWORD (two characters) OR PRESS Q TO EXIT
You can now repeat the procedure or quit.