CHAPTER 3: Installation
29
6. Local Stat Mux Configuration Display Screen
Purpose:
Display the information regarding local stat mux configuration, after selecting item 3 on the
MAIN Menu screen.
Description:
The screen displays the parameters selected for the local stat mux sub-channels. For the Stat-24, the
information is presented on three consecutive screens. To scroll between the screens, press
N
.
Procedure:
No action is required on this screen. After the local configuration information display is no longer required,
you can end it by pressing
Q
. This will return you to the MAIN Menu screen.
7. Local Channel Configuration Screen
Purpose:
Select a local sub-channel for configuration or select local sub-channel parameters duplication
option.
Description:
Configure the local stat mux by selecting the parameters of each local stat mux sub-channel. However, you can
also use the duplication function to copy the parameters of any particular sub-channel to any group of other
sub-channels. Screen selections are as follows: enter
00
to select the local sub-channel parameters duplication
option. To select a local sub-channel for configuration, enter the number of the required sub-channel. Press
Q
to return to the Main Menu.
Procedure
:
1. To select the parameters of any particular sub-channel, type the number of the required sub-channel:
enter the two digits of the sub-channel number (for example,
02
for sub-channel 2,
14
for sub-channel
14). The stat mux will display the LOCAL SUB-CHANNEL CONFIGURATION screen (8).
2. To select sub-channel parameters duplication option, type
00
. The stat mux will display the
DUPLICATE LOCAL CHANNELS PARAMETERS screen.
3. Type
Q
to return to the MAIN Menu screen.
8. Local Sub-Channel Configuration Screen
Purpose:
View the current values of the sub-channel parameters. This screen is used to enter specific
sub-channel parameter configuration screens when changes are needed. The various parameters that you can
select are explained in
Section 3.8.2
.
Description:
The screen displays the current values of the selected sub-channel parameters. In addition, the header shows
the number of the sub-channel whose parameters are displayed.