STAT-4, STAT-8, AND STAT-24
34
Procedure:
To change the status of the RTS-to-DCD transfer for this sub-channel, type the appropriate code number.
The new selection appears in the Current State line.
Type
Q
to return to the Local Sub-Channel Configuration screen (8).
17. Duplicate Local Channel Parameters Screen
Purpose:
Copy the parameters of any desired local sub-channel to a group of other local sub-channels.
Description:
To initiate the duplication, enter the number of the required source sub-channel, and then enter numbers of
the first and last sub-channels of the target sub-channels group.
If you want to perform more than one duplication, always start from the lowest target sub-channel range; for
example, start with the 02 through 10 sub-channels group before duplicating on the 11 through 20
sub-channels group.
After the mux completes the required duplication, you can continue with the duplication of other sub-channels
by entering the number of another source channel. Type
Q
to return to the Local Channel Configuration
screen.
Procedure:
1. Type the number of the required source sub-channel (two digits, for example,
02
for sub-channel 2).
2. Type the two-digit numbers of the first and last sub-channels of the desired target sub-channels group
(range). If you specify the range incorrectly, you will see a message that explains your error. After reading
the message, enter again the correct values.
3. If you want to perform an additional duplication, enter again the number of a source sub-channel. After
its number, you will be prompted for the numbers of the target group.
4. After ending sub-channel parameters duplication, type
Q
to return to the LOCAL CHANNEL
CONFIGURATION screen (7).
18. Diagnostics Menu
Purpose:
Select the control screens for the various test loops that you can activate from the local stat mux, for
diagnostic purposes. See
Chapter 5
for a description of the test loops.
Description:
Use Code numbers 1 through 3 to select the desired test loop type: local loop, remote loop, and modem loop.
Type
Q
to return to the Main menu screen. When you first enter the Diagnostics menu, the Current State line
shows:
ALL TESTS ARE IN OFF STATE.
Procedure:
Type the code number corresponding to the desired test loop type.