background image

2

Dwg Name: 

FSP60W-1390418ART   

Dwg No: 

1390418       

ECO No: 

037614           Rev: 

Pkg Dwg Ref: 

A4   

Color Reference: 

N/A

CONTENTS

•  FSP60W Foldable 60W Solar Panel
•  29205 Anderson Power Pole

®

 (APP

®

) to 8mm DC adapter

•  Instruction Manual

GENERAL SPECIFICATIONS

•  Operating Altitude: 

6562 ft. (2000m)

•  Capacity (Maximum Output): 

60W

•  Solar Cell Type: 

Monocrystalline

•  DC Output: 

60W (Maximum)

•  Open Circuit Voltage: 

22V

•  Maximum Power Voltage: 

18V

•  Port Output (APP

®

): 

18V/3.34A

•  USB Output (USB-A): 

5V/3.0A

•  Operating / Storage Altitude: 

6562 ft. (2000m)

•  Operating / Storage Maximum Humidity: 

<75% non-condensing

•  Operating Temp: 

14° to 122°F (-10° to 50°C)

•  Storage Temp: 

14° to 122°F (-10° to 50°C)

•  Dimensions: 

36.5

"

 x 20.5

"

 x 2

(929 x 522 x 50.8 mm)

•  Weight: 

5.7lbs (2.6 kg)

•  Conformance: 

CE

Specifications subject to change.

WARNINGS

Read, understand, and follow these instructions to ensure safe operation. Failure to observe these warnings can result in risk 

of fire, electric shock, serious injury, and/or property damage.

•  DO NOT 

use the product if it is damaged or modified. Damaged or modified equipment may exhibit unpredictable 

behavior resulting in fire or risk of injury.

•  DO NOT 

subject to impacts or drops. The housing may not show signs of damage, but internal components may 

have been compromised. It is advisable to replace the unit if any such severe events occur.

•  DO NOT 

expose to open flame, heat sources, equipment that produces heat, or extremes in environmental 

temperature.

•  DO NOT 

attempt to repair the solar panel. There are no user-serviceable parts.

•  DO NOT 

immerse in water or other liquids. Avoid spilling liquids into any ports or openings on the device.

•  DO NOT 

let solid foreign objects, such as dirt or job site debris, get into any ports or openings on the device.

•  DO NOT

 route power cables through areas where they can be stepped on or pinched by other objects.

•  DO NOT

 attempt to insert other USB connector types into USB-A port. NOT intended for use with plug types or 

adapters not listed on the product label.

•  STOP

 use immediately if any wires become loose or electronic components are exposed.

ENGLISH

FSP60W-1390418ART.indd   2

FSP60W-1390418ART.indd   2

11/20/20   12:24 PM

11/20/20   12:24 PM

Summary of Contents for FSP60W

Page 1: ...N AIS p 9 ESPA OL p g 5 60W Solar Panel FSP60W Dwg Name FSP60W 1390418ART Dwg No 1390418 ECO No 037614 Rev B Pkg Dwg Ref A4 Color Reference N A FSP60W 1390418ART indd 1 FSP60W 1390418ART indd 1 11 20...

Page 2: ...f it is damaged or modified Damaged or modified equipment may exhibit unpredictable behavior resulting in fire or risk of injury DO NOT subject to impacts or drops The housing may not show signs of da...

Page 3: ...lead to a decrease in service life overheating or fire Extremely cold temperatures below the specified storage range can also harm the performance and service life of the device Keep away from corros...

Page 4: ...lluminated It is only possible to illuminate all three indicators when the device is connected to a load capable of drawing more than 25W of continuous power NOTE Regardless of panel positioning if a...

Page 5: ...ES ESPA OL Panel solar de 60 W FSP60W Dwg Name FSP60W 1390418ART Dwg No 1390418 ECO No 037614 Rev B Pkg Dwg Ref A4 Color Reference N A FSP60W 1390418ART indd 5 FSP60W 1390418ART indd 5 11 20 20 12 24...

Page 6: ...modificado Los equipos da ados o modificados pueden presentar comportamientos impredecibles que pueden provocar incendios o riesgo de lesiones NO lo someta a impactos ni ca das Es posible que la carc...

Page 7: ...brecalentamiento o un incendio Las temperaturas extremadamente fr as por debajo del rango de almacenamiento especificado tambi n pueden afectar el rendimiento y la vida til del dispositivo Mant ngalo...

Page 8: ...ptima cuando los tres indicadores est n iluminados Solo es posible iluminar los tres indicadores cuando el dispositivo est conectado a una carga capaz de consumir m s de 25 W de potencia continua Nota...

Page 9: ...RAN AIS Panneau solaire de 60 W FSP60W Dwg Name FSP60W 1390418ART Dwg No 1390418 ECO No 037614 Rev B Pkg Dwg Ref A4 Color Reference N A FSP60W 1390418ART indd 9 FSP60W 1390418ART indd 9 11 20 20 12 25...

Page 10: ...ou modifi s risquent de produire des effets impr visibles et de causer des incendies ou des blessures N EXPOSEZ PAS l appareil des chocs ou des chutes Le bo tier pourrait sembler intact m me si les c...

Page 11: ...de causer un incendie Les temp ratures froides inf rieures la plage recommand e pour l entreposage peuvent galement courter la dur e de vie de l appareil et nuire son rendement Gardez l appareil loign...

Page 12: ...ssance optimale Les panneaux se trouvent dans une position optimale lorsque les trois indicateurs sont allum s Les trois indicateurs ne peuvent s allumer que lorsque l appareil est connect une charge...

Reviews: