SAFETY DATA
FAILURE TO DISCONNECT AND
LOCKOUT ELECTRICAL POWER
BEFORE ATTEMPTING MAINTENANCE
CAN CAUSE SHOCK, BURNS OR
DEATH.
Hazardous voltage.
Can shock, burn
or cause death.
Hazardous
machinery can
cause serious
personal injury.
FAILURE TO DISCONNECT AND
LOCKOUT ELECTRICAL POWER
BEFORE ATTEMPTING MAINTENANCE
CAN CAUSE SERIOUS PERSONAL
INJURY OR DEATH.
Hazardous or toxic
fluids can cause
serious injury.
IF PUMPING HAZARDOUS FLUIDS
SYSTEM MUST BE FLUSHED AND
DECONTAMINATED, INSIDE AND OUT,
PRIOR TO PERFORMING SERVICE OR
MAINTENANCE.
NOTICE:
THIS PUMP SHALL BE INSTALLED IN ACCORDANCE
WITH THE REQUIREMENTS OF NFPA 58 AND ALL
APPLICABLE LOCAL, STATE AND NATIONAL
REGULATIONS.
DO NOT ATTEMPT TO OPEN THE PUMP
UNTIL YOU HAVE BLED OFF THE
PRESSURE. ON SYSTEMS WITH
METERS, THE DIFFERENTIAL VALVE
WILL KEEP LIQUID UNDER PRESSURE
IN THE PUMP, METER AND PIPING
EVEN WHEN THE HOSE IS EMPTIED.
Hazardous pressure
can cause personal
injury or property
damage.
PUMP DATA
Hazardous voltage.
Can shock, burn
or cause death.
Install, ground and wire to local and
National Electrical Code requirements.
Install an all-leg disconnect switch near
the unit motor.
Disconnect and lockout electrical power
before installation or service.
Electrical supply MUST match motor nameplate
specifications.
Motors equipped with thermal protection automatically
disconnect motor electrical circuit when overload exists.
Motor can start unexpectedly and without warning.
NOTICE:
BLACKMER LP-GAS PUMPS MUST ONLY BE
INSTALLED IN SYSTEMS DESIGNED BY QUALIFIED
ENGINEERING PERSONNEL. SYSTEM DESIGN MUST
CONFORM WITH ALL APPLICABLE REGULATIONS
AND CODES AND PROVIDE WARNING OF ALL
SYSTEM HAZARDS.
2
FAILURE TO RELIEVE SYSTEM
PRESSURE PRIOR TO PERFORMING
PUMP SERVICE OR MAINTENANCE
CAN CAUSE PERSONAL INJURY OR
PROPERTY DAMAGE.
Hazardous pressure
can cause personal
injury or property
damage.
DISCONNECTING FLUID OR
PRESSURE CONTAINMENT
COMPONENTS DURING PUMP
OPERATION CAN CAUSE SERIOUS
PERSONAL INJURY, DEATH OR MAJOR
PROPERTY DAMAGE.
Hazardous pressure
can cause
personal injury or
property damage.
TECHNICAL DATA
Maximum Pump Speed
1750 RPM
Maximum Temperature
240
o
F (115
o
C)
Maximum Differential Pressure
150 psi (10.3 bar)
Maximum Working Pressure
350 psi (24.1 bar)
(Inlet Pr Differential Pressure)
Model No.
Serial No.
Date of Installation:
Inlet Gauge Reading:
Discharge Gauge Reading:
Flow Rate:
INITIAL START UP INFORMATION
NOTE:
These pumps are listed by Underwriters’
Laboratories for liquefied petroleum gas and NH3 service.
INSTALLATION