103-A00 page 2/12
SAFETY DATA
Failure to disconnect and lockout
electrical power or engine drive before
attempting maintenance can cause
severe personal injury or death
Failure to disconnect and lockout
electrical power before attempting
maintenance can cause shock, burns or
death
Hazardous
machinery can
cause serious
personal injury.
Hazardous voltage.
Can shock, burn or
cause death.
If pumping hazardous or toxic fluids,
system must be flushed and
decontaminated, inside and out, prior to
performing service or maintenance
Disconnecting fluid or pressure
containment components during pump
operation can cause serious personal
injury, death or major property damage
Hazardous or toxic
fluids can cause
serious injury.
Hazardous pressure
can cause personal
injury or property
damage
Operation without guards in place can
cause serious personal injury, major
property damage, or death.
Failure to relieve system pressure prior
to performing pump service or
maintenance can cause personal injury
or property damage.
Do not operate
without guard in
place
Hazardous pressure
can cause personal
injury or property
damage
Failure to stop the pump before
adjusting the shaft packing can cause
severe personal injury
Hazardous
machinery can
cause severe
personal injury
.
PUMP DATA
PUMP IDENTIFICATION
A pump Identification tag, containing the pump serial number, I.D. number, and model designation, is attached to each pump. It is
recommended that the data from this tag be recorded and filed for future reference. If replacement parts are needed, or if
information pertaining to the pump is required, this data must be furnished to a Blackmer representative.
TABLE 1 – TECHNICAL DATA
1.5”, 2”, 2.5”, 3”
4”
Maximum Pump Speed
640 RPM
500 RPM
Maximum Operating
Temperature*
240°F (115°C)
Maximum Viscosity*
20,000 SSU (4,250 cP)
Maximum
Differential Pressure*
150 psi (10.3 Bar)
Maximum
Working Pressure*
175 psi (12 Bar)
* Technical Data is for standard materials of construction.
Consult Blackmer Material Specs for optional materials of
construction.
cP = centistokes at fluid specific gravity of 1.0.
INITIAL PUMP START UP INFORMATION
Model No.: ____________________________________
Serial No.: ____________________________________
ID No.: _______________________________________
Date of Installation: _____________________________
Inlet Gauge Reading: ____________________________
Discharge Gauge Reading: _______________________
Flow Rate: _____________________________________