111-B00 Page 2/16
SAFETY DATA
Failure to disconnect and lockout
electrical power or engine drive before
attempting maintenance can cause
severe personal injury or death
Failure to disconnect and lockout
electrical power before attempting
maintenance can cause shock, burns or
death
Hazardous
machinery can
cause serious
personal injury.
Hazardous voltage.
Can shock, burn or
cause death.
If pumping hazardous or toxic fluids,
system must be flushed and
decontaminated, inside and out, prior to
performing service or maintenance
Disconnecting fluid or pressure
containment components during pump
operation can cause serious personal
injury, death or major property damage
Hazardous or toxic
fluids can cause
serious injury.
Hazardous pressure
can cause personal
injury or property
damage
Operation without guards in place can
cause serious personal injury, major
property damage, or death.
Failure to relieve system pressure prior
to performing pump service or
maintenance can cause personal injury
or property damage.
Do not operate
without guard
in place
Hazardous pressure
can cause personal
injury or property
damage
PUMP DATA
PUMP IDENTIFICATION
A pump Identification tag, containing the pump serial number, I.D. number, and model designation, is attached to each pump. It is
recommended that the data from this tag be recorded and filed for future reference. If replacement parts are needed, or if
information pertaining to the pump is required, this data must be furnished to a Blackmer representative.
TECHNICAL DATA
Pump Size
6, 8
Maximum Pump Speed
3600 RPM
Flow Rate at Max. Pump speed
6-8 GPM (23-30 LPM)
Maximum Operating Temperature
240°F (116°C)
Maximum Viscosity
5, 000 SSU (1100 cP)
Maximum Differential Pressure
125 psi (8.6 Bar)
Maximum Working Pressure
200 psi (13.8 Bar)
Technical Data is for standard materials of construction.
Consult Blackmer Material Specs for optional materials of
construction
INITIAL PUMP START UP INFORMATION
Model No.: ______________________________________
Serial No.: ______________________________________
ID No.: _________________________________________
Date of Installation: _______________________________
Inlet Gauge Reading: ______________________________
Discharge Gauge Reading: _________________________
Flow Rate:
______________________________________
Summary of Contents for ProVane PV6B