background image

 

 

 

Sliding Vane Pumps: 5 to 2200 GPM 

Refined Fuels, Liquefied Gases, Solvents,Process

 

Stainless Steel Sliding Vane Pumps 

1 to 265 GPM:  Acids, Brines, Sugars, Syrups, 

Beer, Beet Juice, Cider, Flavor Extracts, etc. 

 

System One

®

 Centrifugal Pumps 

10 to 7500 GPM; Process, Marine 

 

Magnetic Drive Pumps 

Stainless Steel:  14 to 215 GPM 

 

HXL 6, 8 & 10” 
Sliding Vane Pumps 
 
130 to 2,220 GPM 
 
Refineries 
Terminals 
Barges 
Ships 

 

Reciprocating Gas Compressors 

Liquefied Gas Transfer, Boosting, Vapor Recovery 

 

Hand Operated Pumps 

Dispensing, Transfer, In-line 

   

 

Accessories 

Gear Reducers, Bypass Valves, Strainers

 

Visit  

www.blackmer.com

  for complete information on all Blackmer products 

 

 
 
 
 
 
 

1809 Century Avenue, Grand Rapids, Michigan 49503-1530 U.S.A. 

Telephone: (616) 241-1611  •  Fax: (616) 241-3752 

E-mail:  blackmer@blackmer.com    •    Internet Address:  www .blackmer.com 

Summary of Contents for SX3A

Page 1: ...potential for personal injury death or major property damage Warns of hazards that WILL cause serious personal injury death or major property damage Warns of hazards that CAN cause serious personal i...

Page 2: ...mage Do not operate without guard in place Hazardous pressure can cause personal injury or property damage PUMP DATA PUMP IDENTIFICATION A pump Identification tag containing the pump serial number I D...

Page 3: ...o protect the pump from foreign matter Locate the strainer at least 24 0 6m from the pump and have a net open area of at least four times the area of the intake piping Strainers must be cleaned regula...

Page 4: ...iping flow direction Do not operate the pump in reverse rotation to reverse the direction of flow 1 Determine direction of flow where the pump will be installed 2 Confirm pump is installed in piping s...

Page 5: ...valves are fully open and that the drain valves and other auxiliary valves are closed 5 Install vacuum and pressure gauges on the pump in the connections provided These can be used to check actual su...

Page 6: ...internal relief valve settings can cause pump component failure personal injury and property damage Hazardous pressure can cause personal injury or property damage NOTICE The pump internal relief valv...

Page 7: ...unning NOTICE If pumps are repainted in the field ensure that the grease relief fittings 76A are functioning properly after painting Do NOT paint them closed Remove any excess paint from the fittings...

Page 8: ...ne replacement and reassembly 9 Remove the remaining components from the outboard side of the pump as instructed above PARTS REPLACEMENT 1 If any of the O rings have been removed or disturbed during d...

Page 9: ...e the nut by bending the closest aligned lockwasher tang into the slot in the locknut The pump should turn freely when rotated by hand f Tighten the opposite locknut by hand until it is snug against t...

Page 10: ...iquids that set up when inactive OVERHEATING Location Probable Cause Corrective Action Internal relief valve Continual full bypassing of the liquid Properly adjust the relief valve so that the pump wi...

Page 11: ...suction line Damaged or worn pump parts Too much lift for the vapor pressure of the fluid A dirty or clogged strainer Worn vanes Suction Valve Closed Incorrect pump rotation Relief Valve partially op...

Page 12: ...215 GPM HXL 6 8 10 Sliding Vane Pumps 130 to 2 220 GPM Refineries Terminals Barges Ships Reciprocating Gas Compressors Liquefied Gas Transfer Boosting Vapor Recovery Hand Operated Pumps Dispensing Tra...

Reviews: