background image

English

17

:

toring a patch will overwrite any previous patch in that location.

Patches can also be stored via 

)

lackstar’s Insider software or a connected 

)

lackstar 

F

:

-10 footcontroller.

Recalling Patches

Press any Channel button to load that patch.

Pressing the 

)

ank button will cycle through the three banks – green-orange-red. 

The Channel will be preserved, therefore the corresponding patch within the current 

)

ank will be loaded when scrolling through the 

)

anks.

Alternatively, patches can be recalled via 

)

lackstar’s Insider software or any 

connected footswitch.

MIDI

ID

!:

eries amplifiers are able to recall patches via MIDI Program Change messages 

and to dynamically modify amplifier values via MIDI Control Change messages.

To set-up MIDI control, simply connect your MIDI controller’s MIDI Out socket to the 
MIDI In socket on the rear of the amplifier. 

From new, or after a Factory Reset, the amplifier is set to OMNI mode and responds 
to MIDI messages on all MIDI channels.

NOTE:

 You may wish to set the amplifier to respond to MIDI messages on just a 

single MIDI channel. This can be done using the 

)

lackstar Insider software to specify 

which of the 16 MIDI channels to use, or to return the amplifier to OMNI mode.

Recalling Patches

To recall a patch, the MIDI controller should be set to transmit Program Change 
messages (this is usually the case for footcontrollers

. Changing patches on the MIDI 

controller will activate the corresponding patch stored within the amplifier.

Modifying Patch Values

Many patch values (e.g. 

.

ain, 

=

olume, I

:

F – see MIDI Implementation Chart on 

page 102 

 can be adjusted via MIDI Control Change messages in real time. The 

MIDI controller should be set to send the Control Change messages as defined in 
the MIDI Implementation Chart.

24 – 27. Channels 1-4

Channel 1 activates the first patch within the currently active bank.
Channel 2 activates the second patch within the currently active bank.
Channel 3 activates the third patch within the currently active bank.
Channel 4 activates the fourth patch within the currently active bank.

28. Recall Indicator

The Recall Indicator shows if there is a mismatch between the current value of a 
parameter within the amplifier and the corresponding physical front panel control. 
E.g. when you change to a different patch the controls on the front panel may not 
always reflect the setting you are hearing.

To prevent unexpected level jumps in the control you are adjusting, the front panel 
knobs will have no effect on the sound until the knob reaches the current parameter 
value. Once reached, the Recall Indicator flashes twice and the knob ‘takes control’ 
of the value and can increase or decrease the value.

The recall indicator will flash twice each time the physical knob ‘passes through’ the 
value stored within the current patch so you can easily see the programmed value.

Recall is only active for 

.

ain, 

=

olume, 

)

ass, Middle, Treble and I

:

F.

When the Tuner is active the Recall Indicator will flash continuously.

Programmability

Storing Patches

To store the current sound as a patch

1.  Press and hold any of the four Channel buttons for one second. All four    
 Channel 

3

EDs will begin to flash. 

2. Press the 

)

ank button to toggle through the three banks (green, orange, red

  

 

to choose the store location.

3.  Press any of the four Channel buttons once to store the patch in the chosen  
 location. 

The 

3

ED corresponding to the chosen store location will illuminate and the new 

patch will be active.

.

reen bank 

$

 Patches 1-4

Orange bank 

$

 Patches 5-8

Red bank 

$

 Patches 9-12

The amplifier controls can be used to edit the patch at any stage of the store 
process. 

Press the Manual button at any stage to cancel the store process and return the 
amplifier to the last state.

English

16

Summary of Contents for ID:10TVP

Page 1: ...Owner s Manual Designed and Engineered by Blackstar Amplification UK ...

Page 2: ...pparatus 12 6nly use attachments accessories speciÄed by the manufacturer 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to XualiÄed service personnel ervicing is reXuired when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the a...

Page 3: ...oth Condensation can form on the inside of an ampliÄer if it is moved from a cold environment to a warmer location efore switching the unit on it is recommended that the unit be allowed to reach room temperature Unauthorised modiÄcation of this equipment is expressly forbidden by lackstar AmpliÄcation 3td Never push objects of any kind into ventilation slots on the equipment casing Do not expose t...

Page 4: ...d and downloaded via the online community The U connector also allows you to record from your amp directly to your computer An emulated output MP3 line input and MIDI footswitching complete the package y using the unique oice control the patented I F and patent applied for True alve Power ID amplifiers allow unparalleled flexibility and ease of use enabling you to in effect design the sound in you...

Page 5: ...ory reset it will be in ºDemo Mode The sound you hear will reÅect the physical position of the front panel knobs as it will be in Manual Mode All effects plus T P will be turned off All ampliÄer patch locations will contain lackstar factory defaults Patches can be created and stored in Demo Mode but the original factory default patches and settings will be restored each time the ampliÄer is turned...

Page 6: ...e and the T P elector will be deactivated This setting is saved in a patch NOTE With T P off the power amplifier has a linear response and you will not be able to achieve the valve like sag compression and power that T P delivers English 11 USA UK Front Panel 1 Input Plug your guitar in here Always use a good quality screened guitar lead 2 Voice The oice control changes the preamp voicing ranging ...

Page 7: ...Y Delay Press this switch to turn the delay effect on off or focus the effect for editing This setting is saved when you store a patch 13 REV Reverb Press this switch to turn the reverb effect on off or focus the effect for editing This setting is saved when you store a patch With all three of the effect switches the 3ED will show what state it is in LED Effect State Description 3ED not on Effect ...

Page 8: ...ing a patch 19 Master Volume This controls the overall volume of your amplifier Turning it clockwise increases the volume This is a global setting and not saved when storing a patch If the master volume is at zero this allows for silent recording via the emulated output or U The emulated level is controlled via the preamp volume 20 Power Switch This switch is used to turn the amplifier on and off ...

Page 9: ... Channels 1 4 Channel 1 activates the first patch within the currently active bank Channel 2 activates the second patch within the currently active bank Channel 3 activates the third patch within the currently active bank Channel 4 activates the fourth patch within the currently active bank 28 Recall Indicator The Recall Indicator shows if there is a mismatch between the current value of a paramet...

Page 10: ...ad protection circuit and will cause damage to the amplifier Rear Panel 1 Mains Input The supplied detachable mains lead is connected here The lead should only be connected to a power outlet that is compatible with the voltage power and frequency requirements stated on the rear panel If in doubt get advice from a qualified technician 2 Speaker Outputs ID 60TVP ID 100TVP There are two parallel spea...

Page 11: ...ware This is a non storable setting and will be switched off either when the U cable is removed or when the amplifier power is switched off When activated Re amping Mode allows the amplifier to accept a pre recorded dry guitar signal via U and return a fully processed audio signal This return signal can then be captured using recording software on the connected PC or Mac Firmware Update Firmware u...

Reviews: