2.3 ELECTRIC CONNECTION
WARNING: ELECTRICAL WORK ON THIS APPLIANCE MUST ONLY BE DONE BY A
QUALIFIED PERSON AUTHORISED BY THE LOCAL AUTHORITIES TO PERFORM THIS
WORK. ELECTRICAL WORK DONE BY UNQUALIFIED PERSONS COULD RESULT IN A
SAFETY HAZARD OR PROPERTY DAMAGE.
IMPORTANT
: The appliance must be always connected to the ground, according to actual
regulations, by qualified personnel.
The earth connection conductor is green/ yellow
In case of substitution, the section of the cables should not be less than is indicated in the table of
technical characteristics, and concerning the quality; the cables must be types H05RRF.
According to the models, see table of technical characteristics, the alimentation could be, 240 V
~, single-phase current (2+1 conductors) or 415V 2N ~, two-phase current (3+1 conductors), or
three-phase current 415V 3N ~ (4+1 conductors).
A two-phase or three-phase current appliance could be transformed in single-phase current, if the
electric installation is adequate.
To proceed with this transformation see next scheme:
monofasic 240 V ~
2 + 1 conductors
bifasic 415 V 2N ~
3 + 1 conductors
trifasic 415V 3N ~
4 + 1 conductors
POWER CABLE CONNECTION
For a direct connection to the electric network is necessary to mount before the appliance a circuit
breaker according to the electric charge.
Before connection to the electric network, check that the domestic system and the limiter valve
can take the appliance load (see table of technical characteristics)
The electrical connection cable must be according with the technical characteristics.
The supplied cable must be positioned that no point can reach a temperature 50ºC higher than
ambient temperature.
The producer is not responsible if regulations are not respected.
The producer is not responsible for eventual direct or indirect damages owing to a wrong
installation, regulation’s misunderstanding or standards in force not respected.
In the model FD6064 WX (15 A) the plug must be like the figure.
L1 L2 L3 N
L1 L2 N
L
N
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
Summary of Contents for FD6064WX
Page 24: ...TECHNICAL CHARACTERISTICS ...