background image

12

 8-fold IP-/ ASI-TV Modulator

IP/ SFP/ ASI (H.264/ AVC, MPEG2) 

 4x CI 

→ 

ATV (8x AM)

A-PALIOS-IPM4CI

Part N

o

: 5113.81 / 5113.83

This menu lists all services of the adjusted transponders and their CA status. If you want to make settings or changes first the “

Refresh

“ 

button must be pressed to get the current transponder allocation. Select the services for decryption. For each of this selected services 

you can determine, which streams or PID‘s have to be decrypted. That‘s important because the maximum number of the decryptable 

PID‘s is limited. This limit has a different size per CA module.

In the selection boxes “

MPEG 1/ 2 Audio Streams“

 respective “

Subtitling Streams

“ you can choose if all, none or individual streams 

are selectable. 

If you would like to select more than one but not all, select ”

all

“. Then enter in the column “PID block list“ all PID‘s that shall not be 

decrypted.

*

The column “

PID block list

“ lists all PID‘s that shall not be decrypted. The PID‘s can be entered in decimal or hexadecimal format and 

have to be separated by a semicolon. The maximum number of PID‘s is 10.

**

 If  “

Settings all equal

“ is activated, only one service for 

PID selection is offered and the taken settings are automatically transferred to all other services to be decrypted. 

By clicking the “

Test

“ button the CA module will be initialized and all services, which are saved in the CA-service-list, will be tested for 

the current decryption status. Has the test ended, the result is displayed on right side. A green check mark means that the test was 

successful. A red cross means that the test was not successful and the requirements for this service must be corrected, e.g. too much 

PID‘s were selected.

*

  “

Other Audio Streams

“ includes all AC3-, DTS- and AAC-Streams. “

Private Streams

“ selects all streams which are not captured by the other selection

    fields.

** 

Particularly PID‘s can be given here, which are active only at times and no authorisation for decryption is available for them.

Table editing (SDT, PMT, EIT) is performed by defaullt. The CA descriptor 0x09 will be replaced in the PMT through the user-defined 

descriptor 0xFE. If this descriptor is already used by the service provider enable in “

Setup

GUI settings

Tag selection (for decoded 

pid)

“ ( 

»

section 8.2.8). Thus, the option “

DVB tag (decoded TS)

“ is also displayed in multidecryption menu at each service. A user-

defined descriptor from the range of 0x00 to 0xFF will be selected. It should be noted that this descriptor should not already be used 

in the service.

After these settings each of the 4 CA modules can be configured. Each slot displays if the module is initialized, if it is ready and which 

type of module it is.

Initialize each CA moule before setting the CA services. For this purpose select the box “

Reset slot

“. 

Set the mode of the CA PMT update in the next line. You can choose between CA PMT list or CA PMT entry. please note, that CA PMT 

entry is not supported by all CAM‘s.

Some CA modules require the resource “

Date & Time

“ for initializing. Disable this checkbox for all ll other modules.

The CA menu shows the implemented menus. These can be selected individually or sequentially accessed in order to make settings 

or to retrieve information.

By changes in the channel (e.g. transponder switching, CA module change or removal) the menu has to be passed through completely 

for updating the internal tables. For this purpose, as described above, first determine the changes in the signal path and then call 

the multidecryption menu for the affected channels. Reload the channel list again by pressing the “

Refresh

“ button. Then  make the 

appropriate stream selection. This is also necessary if a module has been removed and a free transponder has to be transmitted in this 

channel. Press the “

Send

“ button in the „

CI setup

“ menu to save and send your settings.

Summary of Contents for A-PALIOS-IPM4CI 5113.81

Page 1: ...Professional Headend Solutions Device manual A PALIOS IPM4CI Part No 5113 81 5113 83 8 fold IP ASI TV Modulator IP SFP ASI H 264 AVC MPEG2 ATV 8x AM...

Page 2: ...ED at the ASI socket 5 7 4 4 Status LED at the output coupler 5 7 4 5 LED s at the 10 100 Mbit control port 5 8 Settings by web interface 6 8 1 Network connection to the computer 6 8 2 Setting of indi...

Page 3: ...ht programs from up to eight fed in IP transport streams or from an ASI transport stream and converts these into analogue TV signals to transmit it in cable networks In this case a maximum of eight an...

Page 4: ...s not ready CH 1 CH 8 green permanently on channel operates without error amber permanently on error warnings depending on signal input and or output without sync input sync but in bad quality eg mosa...

Page 5: ...nnection is a GbE connection does not light up at a 10 100 Mbit connection off no GbE connection LINK TRAFFIC amber permanently on cable connection is established flashing data is received off no cabl...

Page 6: ...e A PALIOS IPM4CI has to be connected to PC network using an Ethernet cable The default IP address of the device is 192 168 1 100 In order to access the web interface of the A PALIOS IPM4CI from a PC...

Page 7: ...ree An option to move it on the right side instead is available chapter 8 2 8 All eight channels are listed individually A green LED symbol in front of channel 1 8 means that input and output are sync...

Page 8: ...are listed Setup chapter 8 2 8 Functions across devices like the NIT exchange between devices of the QAMOS group can be done on all listed devices The individual components of a headend are listed wit...

Page 9: ...Again IP address port and transport protocol UDP or RTP have to be entered for each IP channel Press the send button to save the settings Unused ports are disabled by entering the IP address 0 0 0 0 I...

Page 10: ...is included in the monitoring In addition you have to choose when to switch either when one input channel fails or when all monitored channels are failing The switching will occur even no signal is p...

Page 11: ...channels 1 4 Only these can be routed through the CA modules First you select the pathway of transport streams of the 4 channels There are some possibilities for routing First route channel 1 module 1...

Page 12: ...d by the other selection fields Particularly PID s can be given here which are active only at times and no authorisation for decryption is available for them Table editing SDT PMT EIT is performed by...

Page 13: ...he or button Both on the input side as well as on the output side the assignment can be freely selected i e on input side per channel the source IP stream 1 8 ASI TS player can be freely selected for...

Page 14: ...referred program of the transponder If the program is available in multiple languages specify language and subtitle in the next two colums column Output frequency Set the channel for the selected prog...

Page 15: ...see below Selected program variant 2 manual input Program name displays the name of the program which was selected in the input menu Load reloads the program list Service ID service ID of the requeste...

Page 16: ...up to 4 image lines from the following selection Off CCIR 17 CCIR 18 CCIR 330 CCIR 331 Sin x x Ramp As a default the image lines 17 18 330 and 331 are selected The image lines selection is editable i...

Page 17: ...nu Language In this menu the user interface language can be set You can choose between German and English The adjustment can be made either in the navigation tree at the point language or on the top r...

Page 18: ...re B G D K M and L raster In case of D K1 the sound carriers are at 6 5 6 25 MHz D K2 at 6 5 5 74 MHz and D K3 at 6 5 6 74 MHz the raster for M is at 6 MHz and for L at 8 MHz Based on this selection t...

Page 19: ...mented since the start of the GUI Each operation is listed by date time and description If operations have been executed the logged on user who initiated the action is saved too By pressing of the Era...

Page 20: ...1 1 to 192 168 1 99 Along with the DHCP server a local DNS Domain Name Server will be set up To use it in full extent a connected PC laptop must be configured as a DHCP client Note that using Windows...

Page 21: ...h which thresholds trigger traps There are three ways to configure a trap without parameters e g fan on off with a free selectable parameter for a medium priority with a selectable parameter from a li...

Page 22: ...level for all 8 channels in the range from 64 82 dB V If the loop is disabled the output level of the 8 channels can be set in the range of 76 94 dB V The device variant 5113 83 includes an amplifier...

Page 23: ...Amplifier The amplifier can be set and used independently of the A PALIOS IPM4CI It does not influence the device itself or other devices of the headend The adjustment range of amplification is betwe...

Page 24: ...evice causes a reboot i e the device restarts and all stored values are restored If the device must be reset to factory settings please press the reset button until the POWER and SYSTEM LED will illum...

Page 25: ...SFP A PALIOS IPM4 F F F A PALIOS IPM4 192 168 1 103 A PALIOS IPM4 192 168 1 101 A PALIOS IPM4 192 168 1 104 A PALIOS IPM4 192 168 1 102 Management Management Management Management Feed IP stream Feed...

Page 26: ...65 dB S N ratio parallel sound unweighted weighted 65 60 dB Spurious 45 862 MHz 60 dB Max frequency stability 30 kHz Output level stability 0 5 dB Operating parameters Operating voltage 2x 90 240 V 5...

Page 27: ...re Device Software of the A PALIOS IPM4CI Copyright C BLANKOM Antennentechnik GmbH Bad Blankenburg This device software based on top of Linux 3 6 8 is free software you can redistribute it and or modi...

Page 28: ...e Council for the approximation of legislation of the member states Electromagnetic compatibility 2004 108 EC The following standards are met DIN EN 50083 2 2007 04 EN 50083 2 2006 06 Low voltage guid...

Reviews: