background image

5

AMB 307

Part N

o

: 9730.01

COFDM Modulator

ASI-TS 

 DVB-T (COFDM)

B

LINE

8. Programming by web server *

8.1 Main menu

Name of device, item number, module address in head end

Description 

module name (max. 30 characters)

Transport stream 

displays the priority of both TS, if hierarchical   

 

modulation was selected (menu 1)

Input

TS-Input 

displays ASI input respective selection of the   

 

input of the second TS, if hierarch. modulation  

 

was selected. 

Status 

display wether 

SYNC

hronization or   

 

 

noSYNC

hronisation with input

Data rate 

displays the data rate of the TS 

Output

 

 

Channel 

channel selection : 2 ... 69, standard B/G,

                                                                        2 ...134, standard M
Attenuation 

adjustment range 0 ... 31.5 dB

RF signal: 

selection: On/ Off

Transmission mode 

selection: 2k/ 8k

Constellation 

selection: 16 QAM,  64 QAM, QPSK

Bandwith: 

selection: 5, 6, 7, 8 MHz

Guard intervall: 

selection: 1/32, 1/16, 1/8, 1/4

Code rate: 

selection: 1/2, 2/3, 3/4, 5/6, 7/8

Status

 

 

 

Operating mode
  COFDM-Modulator 

according adjustment menu 1

Hierarchical
  modulation 

according adjustment menu 1

Mode TS-Processing  

DVB-Standard/ TNT-France according menu 1 

NIT-Processing 

On/ Off according adjustment menu 5

CAT-Processing 

On/ Off according adjustment menu 5

Change TS-Identificat.  On/ Off according adjustment menu 5
Program filter 

On/ Off according adjustment menu 3

Data rate overview 

see menu 4

Operating mode 

selection: On/ Off/ Reset

SNMP-Trap message 

selection: On/ Off, if SNMP option in HCBx00

 

enabled, otherwise “locked“ displays

Level monitoring 

selection: On/ Off

Factory settings 

setting the default values (see menu 9)

Routing to the appropriate adjustment menu
Extended settings 

see menu 1

NIT table 

see menu 2

Program filter 

see menu 3

Table processing 

see menu 5

Software overview 

see menu 7

Status 

see menu 8

 * Further details on this are to be found in the HCB manual

Summary of Contents for AMB 307

Page 1: ...tus LED s 4 8 Programming by web server 5 8 1 Main menu 5 8 2 Extended settings 6 8 3 NIT entries 6 8 4 Program filter 6 8 5 Data rate overview 6 8 6 Table processing 7 8 7 Configuration channel list...

Page 2: ...cal data With all work the defaults of the DIN EN 50083 have to be considered Especially the safety relevant execution of the DIN EN 60728 11 2 is necessary 2 Device variants AMB 307 9730 01 ASI TS DV...

Page 3: ...ming mode on each module by selecting the line BEB x00 and the module position 01 15 at the Headend Controller HCB x00 yellow LED illuminates until the beginning of the parameter adjustment Adjustment...

Page 4: ...eaning of LED signals 7 1 LED s for the ASI ports Colour Status Meaning of display green permanently on ASI channel has been configured as input flashing no ASI signal yellow permanently on ASI channe...

Page 5: ...Hz Guard intervall selection 1 32 1 16 1 8 1 4 Code rate selection 1 2 2 3 3 4 5 6 7 8 Status Operating mode COFDM Modulator according adjustment menu 1 Hierarchical modulation according adjustment me...

Page 6: ...e item number module address in head end Program filter configuration Filter function selection On Off Other transporder information pass or drop of additional informations e g electronic program guid...

Page 7: ...nge 0 65535 Transport stream Change TS Identific selection On Off Transport stream ID adjustment range 0 65535 Network ID adjustment range 0 65535 8 7 Configuration channel list LCN menu 6 Name of dev...

Page 8: ...COFDM BLINE 8 8 Software overview menu 7 Name of device item number module address in head end Software version Controller of terminals board FPGA Bootcontroller COFDM modulator TS Mux FPGA TS manage...

Page 9: ...memory error memory up converter Original TS ID s display transport stream ID and network ID Information Temperature Temperature of terminals board Device number display of the device number Device in...

Page 10: ...12 FPGA TS Packed buffer overflow WARNING overflow of TS packet buffer 13 Data overflow CRITICAL overflow of data 14 Sync error data FIFO CRITICAL data FIFO doesn t work correctly 15 No response to OP...

Page 11: ...put too large WARNING RF output too large at the Up converter 23 Up Converter ok INFORMATION Up converter works correctly 11 Block diagram 12 Head end bus structure ASI frontend PID filter PID filter...

Page 12: ...Max output level 115 dB V Level adjustment range 0 31 5 dB 0 5 dB steps Channel allocation adjacent channel ability Connector F socket Impedance 75 Return loss 18 dB 45 MHz 1 5 dB Octave Signal quali...

Page 13: ...ntifier PMT Program Map Table PSI Program Service Information QAM Quadrature Amplitude Modulation QPSK Quadrature Phase Shift Keying RF Radio Frequency SDT Service Description Table SI Service Informa...

Page 14: ...herewith declares the conformity of the product Product name COFDM Modulator Type AMB 307 Product number 9730 01 according to the following regulations EN 50083 2 EN 60728 11 as far as relevant and ad...

Reviews: