background image

6

ATB 19x

Part N

o

: 9848.xx

ASI - TV Transmodulator

ASI 

 ATV (AM) 

Technical data

Audio output                                                 0,7 V

eff

 at 10 kΩ  

Connector                                                    MCX socket
Video output                                                1 V

ss

 at 75 Ω  

Connector                                                    MCX socket

9. Programming by Web server*

9.1 Main menu

Name of device, item number, address in head end

Description

  

Name of programme (max. 30 characters)

Input

Status  

display wether 

SYNC

hronization or

 

noSYNC

hronisation with Input

Decryption settings

(will only be available if “BISS decryption” option is on)

BISS key

          

input of the 12-digit code in BISS mode 1

   

or of the 16-digit code in BISS mode E

BISS-E injected ID

    

input of the 14-digit code in BISS mode E,

                                

no input in BISS mode 1!

Program settings

Program listing  

see Menu 2

Service ID  

freely selectable (0...65535)

Language  

freely selectable (0...255)

Language code  

shows the code for the language selected

Service type  

shows the type of service selected

 

(TV, radio)

Output

Frequency table  

channel selection:

  standard B/G  

  channel 2..69

  standard D/K 

  channel R1.. 69

Attenuation  

adjustment range 0 ... 31.5 dB

Module settings

Operating status  

selection: On, Off, Reset

Transmit trap  

On/Off, if SNMP option in HCB x00

  

enabled,otherwise “locked“ display

SYNC check  

checks SYNC at input port. selection:

 

fast, normal, slow

Level monitoring  

at output port. selection: On, Off

Routing to the appropriate adjustment menu:
Software option  

see menu 1

Extended settings  

see menu 3

Status  

see menu 6

Default set  

see menu 5

9.2 Software option (menu 1)

Name of device, item number, address in head end

Dialogue for entering code to activate the “test line”
(CKB 101), “subtitling” (CKB 102) and “BISS decryption” 
(CKB 104) software options. When the page is called up, the 
current state of activation for the relevant option will be dis-
played.

 * Further details on this are to be found in the HCB manual

Summary of Contents for ATB 19 series

Page 1: ...4 8 Optional hardware variants 4 8 1 IF interface 4 8 2 Additional A V monitor outputs 5 9 Programming by Web server 6 9 1 Main menu 6 9 2 Software options 6 9 3 Loading the programme list 7 9 4 Exten...

Page 2: ...standard B G ATB 191 9848 08 ASI ATV AM A V standard B G ATB 191 9848 09 ASI IFI ATV AM standard B G ATB 192 9848 21 ASI ATV AM standard D K 1 ATB 192 9848 22 ASI ATV AM standard D K 2 ATB 192 9848 24...

Page 3: ...aps because the output cable is disconnected a warning and display item for a level fault may also appear When the fault has been identified the appropriate SNMP Trap message will be sent Use of this...

Page 4: ...flashing error warnings depending on signal ASI without sync e g when there is no input signal service settings are not valid service is decrypted ADDR yellow illuminated or flashing remote control ma...

Page 5: ...input 3 If a module with IF interface is mounted to the wall the usage of SMA angle plugs for the interface side of the connection cable is recommended The cables have to be screwed onto the interfac...

Page 6: ...e code for the language selected Service type shows the type of service selected TV radio Output Frequency table channel selection standard B G channel 2 69 standard D K channel R1 69 Attenuation adju...

Page 7: ...I ATV AM 9 3 Loading the programme list menu 2 This menu contains a list of all services contained in the data stream Language selection can take place here if available Any service is adopted or give...

Page 8: ...will only be available if Subtitling option is on DVB languages index freely selectable 0 255 DVB language code shows the code for the language selected Use extended ID s selection yes no Composition...

Page 9: ...ely selectable 0 16383 Teletext PID freely selectable 0 65535 VBI PID freely selectable 0 65535 Subtitle PID freely selectable 0 65535 Composition Page ID freely selectable 0 65535 Ancillary Page ID f...

Page 10: ...data shows detailed information about current VPS data Current WSS data shows detailed information about current WSS data The following will only be displayed if the test lines option is switched on T...

Page 11: ...ror CRITICAL PLL at output not activated ATB 19x start Edit or Close Power status On Off TV sound Audio gain 6 20 dB Video settings Video output On auto off auto colour palette bar Colour system PAL S...

Page 12: ...al 18 Tonmode Dual invers INFORMATION Sound mode set as dual inverse 12 Block diagram ASI Frontend MPEG decoder Video Audio processing IF RF Vestigial sideband IF modulator 2x FM modulator ASI RF 45 8...

Page 13: ...kHz Output frequency range 45 862 MHz Tuning steps 10 kHz Output level max 116 dB V Range for level adjustment 0 31 5 dB 0 5 dB steps Channel allocation adj channel compatible Connector F socket Impe...

Page 14: ...rogram Clock Reference PDC Program Delivery Control PID Packed Identifier PMT Program Map Table PLL Phase locked loop RF Radio Frequency SECAM S quentiel couleur m moire SNMP Simple Network Management...

Page 15: ...h declares the conformity of the product group Product name ASI Transmodulator Type ATB 19x Product number 9848 xx according to the following regulations EN 50083 2 EN 60728 11 as far as relevant and...

Reviews: