11
EMA x08/407
Part N
o
: 917x.xx
ENCODER/ MULTIPLEXER
SDI/ A/V
→
ASI(TS) & IP(TS)
HDMI
→
ASI(TS) & IP(TS)
A
LINE
use DHCP:
[ON/ OFF]
Allocation of IP address, default : 192.168.2.86
“ON“
One-time at the start an IP address via a DHCP server is requested. If the probe fails, will use the default IP address.
“OFF“
The default IP address is used.
IP-Address:
[0.0.0.0 ... 192.168.2.86 ... 255.255.255.255]
A default IP address for the case that “use DHCP“ is set to “OFF“, or no DHCP server could be reached.
IP-Subnetmask:
[0.0.0.0 ... 255.255.255.0 ... 255.255.255.255]
The mask corresponding to the IP address.
IP-Gateway:
[0.0.0.0 .. 255.255.255.255] An IP address for a possibly used gateway in the network. The definition of a gateway address
is only required if the device is to send SNMP traps to a server that is only accessible via a gateway.
SNMP Trap IP-Addr:
[0.0.0.0 .. 255.255.255.255] IP address to a possilble used SNMP trap manager.
Important device functions are constantly monitored and possibly forwarded as an SNMP trap to a superior manager. Depen-
ding on the hardware fitting the following system messages are sent:
ENCODER
ASI-IN
Device
EncA no input
ASI-IN overrun
Fan OFF
EncA error
Encoder TS overrun
Fan ON
EncB no input
ASI-In no input
Device has started
EncB error
ASI-In error
Reload Parameter
EncC no input
Default error
EncC error
EncD no input
EncD error
3.3.2.2.2 General selection
Fig. 7: Standard operating mode (EMA 408 , 508, 608, 708)
Setting the operating mode is based on the equipped hardware. Changes in this section need to be saved (“Save to Device“) to
adapt the relevant configuration entries in the following sections and provide for input.
PSI Mode:
[DVB/ ATSC]
Multiplexer mode according to the national transmission standard
ASI Main Input:
[OFF/ Loop
→
ASI-Out/ Mux with Intern/ Flt-DROP & MUX]
“OFF“
Input deactivated;
“Loop
→
ASI-Out“
Loop-through of the signal ASI-IN
→
ASI-Out;
“Mux with Intern“
All services of the TS at the ASI input can be multiplexed with the internally generated services to a common TS.
„Flt-DROP & MUX“
Selected services of the TS at the ASI input can be multiplexed with the internally generated services to a common TS. The
selection of the filtered out services must be made in this mode by the function call “Drop Services“ in the header of the confi-
guration.
Warning:
If there are overlaps of the PID/ SID the relevant services of the TS from ASI-IN will be deleted..
Slot A..D (Encoder moduls):
[OFF/ CVBS/ SDI, emb. Audio/ SDI, anal. Audio/ [ASI-TS]/ [CVBS-SPDIF]/ [SDI-SPDIF]/ Intern/ Transcoder
/ Decoder]
The hardware configuration is automatically detected. The purpose of their possible modes are provided.
“OFF“
Module deactiviated.
“CVBS“
(available in EMA 308, 408, 608)
The input signal is an analogue A/V signal (SD).