background image

 

 

MPEG4 HD IP Encoder User Manual 

 

About This Manual 

To whom it may concern

 

This user manual has been written to help people who have to use, to integrate and to 

install the product. Some chapters require some prerequisite knowledge in electronics 

and especially in broadcast technologies and standards.  

 

Disclaimer 

No part of this document may be reproduced in any form without the written 

permission of the copyright owner. 

The contents of this document are subject to revision changes without notice due to 

continued progress in methodology, design and manufacturing. We shall have no 

liability for any error or damage of any kind resulting from the use of this document. 
 

Copyrights  

This document contains  some confidential information. Its usage is limited to the 

owners of the product. It shouldn't be copied, modified, or translated in another 

language without prior written authorization from us.  

 

 

 
 
 
 

 

Summary of Contents for EMU-8500

Page 1: ...MPEG4 HD to IP Encoder Installation and operation Instructions EMU 8500 Series 8 24 Inputs depending on ordered device...

Page 2: ...roduced in any form without the written permission of the copyright owner The contents of this document are subject to revision changes without notice due to continued progress in methodology design a...

Page 3: ...IFICATIONS 2 1 4 BLOCK DIAGRAM 3 CHAPTER 2 INSTALLATION GUIDE 5 2 1 GENERAL PRECAUTIONS 5 2 2 POWER PRECAUTIONS 5 2 3 DEVICE S INSTALLATION FLOW CHART ILLUSTRATED AS FOLLOWING 5 2 4 ENVIRONMENTAL REQU...

Page 4: ...ormat support audio gain adjustment Support 1 ASI output optional as copy of the MPTS Support IP output over UDP and RTP Nx SPTS 1x MPTS Support QR code LOGO OSD insertion support Null PKT Filter func...

Page 5: ...tment without B Frame Audio Encoding MPEG 1 Layer 2 Sampling rate 48KHz Resolution 24 bit Bit rate 64kbps 128Kbps 192kbps 224kbps 256kbps 320kbps 384kbps Multiplexing Maximum PID Remapping 180 input p...

Page 6: ...Author RRi 3 Version 1 0 Date 13 July 2017 EMU 8500 series operation instructions docx MPEG4 HD IP Encoder User Manual 1 4 Block Diagram...

Page 7: ...MPEG4 HD IP Encoder User Manual 1 5 Appearance and Description Front and Rear Panel Illustration 1 Power supply and Grounding Pole 2 8 24 HDMI input 3 Reset Key 4 Data Port Indicator 5 ASI output port...

Page 8: ...ating on an open wet floor Make sure the extension cable is in good condition Make sure the power switch is off before you start to install the device 2 3 Device s Installation Flow Chart Illustrated...

Page 9: ...re must be as thick and short as possible Users should make sure the 2 ends of grounding wire are well electric conducted and not corrosive It is prohibited to use any other device as part of groundin...

Page 10: ...he Login interface Insert the Username and Password Both default Username and Password are admin and then click OK to enter the device setting menu Note We recommend using the newest version of the br...

Page 11: ...utput settings PCR Correction should be used to assure this method for the receivers for smooth streaming Parameters TS Config From the menu on the left side of the WEB IF selecting TS Config displays...

Page 12: ...n Parse Programm initialize the reading and reloading of the input data Configure Input Area and Output Area with buttons in Operation Area Instructions are as following Select the Input channels to p...

Page 13: ...erflow so you need to reduce the amount of TV services for this TS To enable disable the PID remapping almost not necessary To refresh the input program information To refresh the output program infor...

Page 14: ...ID which is configurable according to your needs then click set Parameters IP Stream This encoder supports TS to output in IP 8 12 16 20 24 SPTS and or 1 MPTS format through the DATA1 and DATA2 port S...

Page 15: ...here Parameters OSD On Screen Display as Overlay Selecting OSD will show the interface to configuration the OSD parameters Enable disable IP address port number Bitrate CBR maximum select UDP or RTP t...

Page 16: ...using the FireFox browser Enter your text here Select the text color and background color Put your caption anywhere Select to configure logo TEXT Caption or a QRcode Browse and select the Logo which h...

Page 17: ...to set network parameters DATA 1 GbEthernet DATA2 100BaseT can be selected for the Stream outputs The settings can be done independently Do not forget to take them by APPLY System password From the l...

Page 18: ...he factory defaults System Configuration From the menu on left side of the webpage click Configuration will display the sub menu where to save restore factory setting backup load your configurations S...

Page 19: ...707102004 pkg Please upgrade it on firmware page by selecting Host option 2 SOMETHING_ENCODER_12_Ver1 4_20170629_0923 bin Please upgrade it on firmware page by selecting Host option 3 DX224S_Encoder_v...

Page 20: ...Author RRi 17 Version 1 0 Date 13 July 2017 EMU 8500 series operation instructions docx MPEG4 HD IP Encoder User Manual UPGRADE confirm 2 next file...

Page 21: ...Author RRi 18 Version 1 0 Date 13 July 2017 EMU 8500 series operation instructions docx MPEG4 HD IP Encoder User Manual last...

Page 22: ...EMU 8500 series operation instructions docx MPEG4 HD IP Encoder User Manual Before NOW REBOOT by ON OFF ON Switch at the rear panel But wait a few seconds before switching ON again After upgrading th...

Page 23: ...peration instructions docx MPEG4 HD IP Encoder User Manual System Date Time Selecting Date Time will show the menu to set date and time and NTP options for the device System Log Selecting Log will sho...

Page 24: ...to 45 C Assure good ventilation for the heat sink on the rear panel and other heat sink holes if necessary Checking the input AC within the power supply working range and the connection is correct be...