background image

GENERAL

The agile Audio/Video Modulator VMB 195 is a module of the B-LINE headend 
system which is conceived as a complete system for middle sized distrubition 
networks.
The module generates an analog cable-TV signal at the output.
All modules are programmed at the central control unit (HCB 100) and are 
working independently afterwards.
The status of the module (channel) is displayed via colored LEDs:

· Red  

- permanent

Modul in Standby mode

- flashing

Hardware error

· Green

- permanent

Module ok

- flashing

Signal error

· Yellow

- permanent

Remote access

- flashing

Data transfer

DEVICE VARIANTS

VMB 195       9228.51

A/V 

®

 VHF/ UHF

[45  … 862 MHz]

9650.03:                 

   

Version 2.34

9650.04/ 05:

Version 3.18

Minimum software required for  HCB 100 (Headend Controller):

Pic. 02

Pic. 01

AUDIO/VIDEO - MODULATOR 

A/V 

®

 ATV (AM)   Standard M/N

B

LINE

STANDBY

READY

ADDR.

Operating voltage bus/
Control bus

TV RF Output

VIDEO

IN

AUDIO

IN

Video input

Audio input

LED “STANDBY” (red)

LED “ADDR.” (yellow)

LED “READY” (green)

Address selection switch

TV - RF

OUT

X1

X2

VMB 195

PROGRAMMING

Output

Video adjustments

Audio adjustments

Frequency

45000...862000 kHz

Attenuation

               0...31.5 dB

Video control                                     On/Off

Program name

Start - VMB 195

Audio impedance 

       600/12000 Ohm

Audio signal              balanced./unbalanced
Audio level                                  -8...+7 dBV
Audio mode

      

Mono L/ Mono L+R/ External

End - VMB 195

Module adjustments

Operating status                                On/Off
Level control/monitoring                    On/Off

Adjustment with the Headend Controller

Adjustment with the PC / Laptop

·

Adjustment of the addresses at the Bus Extender BEB 100 and at the 
modules

·

Activation of the programming mode of each module by selecting the 
line (BEB 100) and the module position (01... 15) at the Headend 
Controller(HCB 100)

®

 yellow LED will be lit up til the beginning of the parameter 

adjustment

·

Adjustment of the VMB 195 parameter (see Pic.02)

®

 green LED is lit up

·

After the programming the VMB 195 will be automatically switched into 
the operating status

®

 yellow LED lights up briefly / green LED is lit up

·

Condition for the remote programming is an “online - connection” 
after IP - standard and an ethernet connection at the PC / Laptop

·

Adjustment of the line / position addresses at the Bus Extender BEB
100 as well as at the modules

·

At the Headend Controller HCB 100 IP - address input
(e.g. 192.168.001.001)

·

For “direct connection” between a PC and HCB 100 use a crossed 
patch cable (RJ 45)

·

For connection over a deviation use an uncrossed patch cable

·

HTML - browser start-up and put in IP - address as target address

·

If connected correctly the HTML - control surface at the PC will open up 
and a blue LED (LINK) at the HCB 100 will be lit up

·

All adjustment of the modules are specified at the control surface

The manual instructions of the Headend Controller HCB 100 and the Bus Extender BEB 100 have to be considered!

FUNCTION DESCRIPTION

The video processing contains a video low pass with a sound trap, a group delay-pre-equalization, clamping circuit and a switchable video AGC. 
The video AGC function requests one white pulse per field in any line within the source signal (white level adjustment control); alternatively AGC 
has to be deactivated. The magnitude of the residual carrier is determined by video amplitude of the input signal in this case. The audio 
processing contains a symmetric input amplifier, an audio low pass, a level setting element and a switchable audio summing unit. These unit  
allows remote accesses via corresponding contacts into the audio socket (table 01). There is the possibility to configure an asymmetric audio 
input. An electronically switch connects pin 4 and 5 inside the device on ground. Analog video and audio signals are fed to separate modulators 
and summarized at IF mixer. After IF filtering follows the conversion in the wanted output channel by the help of a duplex frequency conversion. 
The operation of high level mixers and fractional N-PLL's assure a high output performance. The output channel is free adjustable between 
45…862 MHz. The modulator is adjacent channel fitted at the output. The device is equipped with a monitoring circuit for the incoming video 
signal and the RF output signal. The green LED is flashing in case of video input signal loss. If the output level is failing the red LED will be 
flashing. The automatically reference level adjustment of the output signal follows after programming (level, frequency), after restart, earliest after 
100 sec. The same error messages can be displayed in case of mismatch or interrupted output cable. A TRAP – message is triggered after 
recognition of a failure. This option is adjustable.

SNMP - Trap messages:      Bus Error               Level Error                PLL Error

Video signal error

SNMP

managed by

gile

SNMP

managed by

gile

gile

SNMP

managed by

AUDIO / VIDEO MODULATOR

A/V 

®

 

ATV (AM)

Type: 

VMB 195   

Part-No.:

9228.51

-                                                                                             
VIDEO IN                                 0.8 … 1.3 V        

pp

AUDIO IN                                  -8 … +7 dBV
TV-RF OUT                           45 … 862 MHz
OUTPUT LEVEL                    max. 56 dBmV
TV STANDARD                                      M/N
SUPPLY CURRENT                           0.55 A