VENTURI BLAST GUN TUNING :
WATCH THE VIDEO FROM BLAST-IT-ALL
®
https://www.youtube.com/watch?v=dKT9XeFhNNY
1.
Attach & Secure Vacuum Gage Hose to the
Bottom of the gun.
Vacuum Gauge Part # 011267
Vacuum Gauge Kit Part # ( TBD )
2.
Attach & Secure Compressed Air (80psi) Hose
to the Orifice Inlet.
3.
Open Air Flow into the Orifice Inlet and Adjust
the Orifice Inlet
IN or OUT
until 15 ~ 18 in Hg
Vacuum is Achieved. Tighten Lock Nut to
Maintain Position.
4.
When Range of Vacuum Can Not be Achieved,
Part/Parts Replacement will be Required.
© 2020 Hess & Associates
Man. # 561 v02-02 8/2020
Page 16
Summary of Contents for LB4024
Page 21: ...Little Blaster LIGHT BOX ASSEMBLY PARTS 2020 Hess Associates Man 561 v02 02 8 2020 Page 19 ...
Page 22: ...Little Blaster MACHINE AIR CONTROLS PARTS 2020 Hess Associates Man 561 v02 02 8 2020 Page 20 ...
Page 25: ...Little Blaster Electrical Diagram 2020 Hess Associates Man 561 v02 02 8 2020 Page 23 ...