19
Problem:
The steel shot in the shot hopper contains an excessive amount of concrete dust.
Possible Solution:
Verify that the vacuum has good suction. If this does not resolve problem,
then increase the travel speed of the BP-9-1 10V to reduce amount of concrete being removed. If
this does not produce an adequate profile, then make additional passes over the floor surface.
Problem:
BP-9-1 10V or dust collector is emitting concrete dust.
Possible Solution:
Verify there are no holes in the duct hose leading from the BPS-110V to the
dust collector. Verify filters in the dust collector are properly installed and are clean. If
necessary replace filters in dust collector.
Problem:
Steel shot is being sucked into dust bin.
Possible Solution:
Dust collector is producing too much suction for the size of shot being used.
Restrict air flow on dust collector.