16
5.6
Replacing a bigbag
ATTENTION! Wear a dust mask of at least class FFP3!
1
Shut down the rotating valves by pushing the red button the control box.
2
Remove and close the funnel of the BigBag.
3
Remove the bigbag from the dust collector.
4
Place a new pallet and bigbag, sleeve the funnel on and secure it with the pull strap.
5
Turn the rotating valves on by pushing the green button on the control box.
5.7
Silencers
The silencers on top of the dust extractor reduce the noise emission.
The 1
st
silencer will close automatically when starting up the fan-units.
Starting up with open silencers can cause start-up failures and could cause excessive wear of the v-belts.
IMPORTANT NOTE !
Always close off the inlet of the dust collector when running the pulse cleaning cycle!
Failure to do so results in blown out dust, which can be hazardous to the health !