4. Initial operation
Before using the machine it is essential to inspect the machine.
It is not permitted to use the machine if the machine safety is not according the
checkpoints below.
Checkpoints of electrical safety
Use only extension cables for extending the main cable that are sized and marked
in accordance with the overall power consumption of the machine.
Electrical cables must be rolled entirely off of the reels.
Any damage to electric cables is not permitted
Use an electrical power supply connection with earth connection.
The main switch of the machine should be put to ‘Off’ before connecting to the
power supply.
The power supply connection 2b (see paragraph 2) is under active voltage, even
when main switch 2a is put to ‘Off’. In ‘Off’ position this supply can be used for
extension purposes (such as light).
Maximum amperage : the dust collector and connected tools must not exceed 16
Amps.
Functions
The following functions are available :
Main-switch 2a
0
dust collector ‘Off’.
1
dust collector ‘On’.
A
Automatic mode (dust collector is activated by the connected tool.
RA
Automatic mode plus automatic filter cleaning. When the filters clog up and the
volume stream gets to low, the shaker cleaner is automatically actuated.
Selection switch 2d and filter control 2c
This switch must be adjusted when the dust collector operates in mode A or RA (main-
switch positions).
With this switch the volume stream of the dust collector is observed. When the volume
stream gets too low due to clogged filters, filter control 2c lights up and an acoustic signal