Disassembly (refer to figure 7.4 on previous page):
1
Unscrew
the
cover.
2
Unscrew the motor fastening screws.
3
Move the motor toward the bearing-unit using tensioning screw
attached
to
the
motor
base.
4
Remove
the
V-Belt.
Fig.
7.5
Assembly:
1
Put on a new V-Belt.
2
Move the motor up to the operator panel using tensioning screw
attached to the motor base.
3
Hand tighten the motor fastening screws.
4
Stretch the belt tension with the tensioning screw attached to the
motor base.
(Note the max permissible tension according to Fig. 7.6).
5
Tighten the motor fastening screws
6 Screw
on
the cover.
© Copyright Blastrac