VENTO V50-1 / V50-1  S / V50-1 Pro / V50-1 S Pro

MODIFICATIONS AND OPTIONS

VENTO V50-1

The unit for the wall thickness from 250 up to 470 mm. The control panel 

and the power unit are available on separate order.

VENTO V50-1 S

The unit for the wall thickness from 120 up to 430 mm. The control panel 

and the control unit are available as special accessories. 

VENTO V50-1 Pro

The unit for the wall thickness from 250 up to 470 mm. Equipped with the 

control panel and the control unit SEA-T12.

VENTO V50-1 S Pro

The unit for the wall thickness from 120 up to 430 mm. Equipped with the 

control panel and the control unit SEA-T12.

DELIVERY SET

 

Unit - 1 item;

 

Fixing set - 1 item;

 

SEA-T12 - control and power unit for Pro models - 1 item;

 

Cable Unitronic LIYY UL CSA 5xAWG/7 (5x0.25), 3 m long - 1 item; 

 

Operation manual - 1 item;

 

Packing box - 1 item.

 

 ATTENTION

                                   
                                   

Make sure the unit has no visible transport damages 
while accepting the goods. Check the ordered and the 
delivered goods for compliance.

Fig. 3. VENTO V50

 -1

Fig. 2. Unit operating logic in winter period

Fig. 5. VENTO V50-1 S

Fig. 4. VENTO V50-1 Pro

Fig. 6. VENTO V50-1 S Pro

Phase 2 (70 seconds)

Air supply to the room

Phase 1 (70 seconds)

Air extraction from the premise

OUTSIDE

OUTSIDE

INSIDE

+17 °С

+17 °С

-7 °С

+20 °С

+20 °С

-10 °С

Summary of Contents for 4058448022678

Page 1: ...VENTO V50 1 SINGLE ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY OPERATION MANUAL EN...

Page 2: ...Safety rules 3 Transportation and storage rules 3 Manufacturer s warranty 3 Design and operating logic 4 Modifications and options 5 Delivery set 5 Technical data 6 Mounting 7 Connection and control...

Page 3: ...icky substances or fibrous materials The appliance is not designed for use in an inflammable and explosive medium Do not close or block the intake or exhaust vent of the appliance not to disturb the n...

Page 4: ...SEA T12 or the control panel SEA is used for operation mode control The delivery set of the units VENTO V50 1 Pro V50 1 S Pro includes the control and power unit SEA T12 consisting of the control pane...

Page 5: ...Pro The unit for the wall thickness from 120 up to 430 mm Equipped with the control panel and the control unit SEA T12 DELIVERY SET Unit 1 item Fixing set 1 item SEA T12 control and power unit for Pro...

Page 6: ...0 021 0 026 Max air flow m3 h 26 53 Sound pressure level at 1 m distance dB A 24 34 Sound pressure level at 3 m distance dB A 14 24 Outdoor sound pressure attenuation dB A 19 Transported air temperat...

Page 7: ...opic air ducts outer ventilation hood and laying out of electric cables final mounting before commissioning of a house It includes installation of the regenerator the filter connection of the ventilat...

Page 8: ...the back part of the ventilation unit Fig 14 7 Remove a screw from the bottom part of the ventilation unit and take off the front grille 8 Insert the dowels 5x25 in the wall and fix the ventilation u...

Page 9: ...l using the screws 4x40 from the delivery set 13 Install the front part of the outer ventilation hood 14 Install the control panel SEA T12 with a power unit inside a prepared hole in the wall see Fig...

Page 10: ...ery set of the unit model The control and power unit SEA T12 consists of a control panel and a 12 W power transformer Fig 22 In case of the control panel SEA either power transformer AT 12 or AT 40 ar...

Page 11: ...tion mode is determined by positioning the jumper JMP1 on the ventilation unit circuit board The jumper positioned in Flow In position sets the unit to supply mode and the jumper positioned in Flow Ou...

Page 12: ...5 The socket connectors of the connecting cable supplied with the unit are marked 1 to 5 and must be connected to the controller socket connectors marked 11 15 for outputs or 21 25 for inputs Cable ch...

Page 13: ...2W transformer wire leads to the contacts A1 35 36 of the controller A1 SEA using the socket connector at the cable K2 The cable is included into delivery set of the 40W transformer model Then connect...

Page 14: ...ow green white grey brown yellow green white 1 grey 2 brown 3 yellow 4 green 5 white 1 grey 2 brown 3 yellow 4 green 5 white 1 grey 2 brown 3 yellow 4 green 5 white 1 grey 2 brown 3 yellow 4 green 5 w...

Page 15: ...year Remove the screw in the bottom part of the fan grille remove and clean the grille Disconnect the wires from the ventilation unit by using the connectors Remove the four screws and take off the v...

Page 16: ...the approximation of the laws of the Member States relating to electromagnetic compatibility This certificate is issued following test carried out on samples of the product referred to above Approval...

Page 17: ..._____________________________________________ _______________________________________________________________________________________ __________________________________________________________________...

Page 18: ..._____________________________________________ _______________________________________________________________________________________ __________________________________________________________________...

Page 19: ..._____________________________________________ _______________________________________________________________________________________ __________________________________________________________________...

Page 20: ...www blaubergventilatoren de VENTO V50 1 v 1 6 EN...