www.blaubergventilatoren.de
9
VENTO V50-1 / V50-1 S / V50-1 Pro / V50-1 S Pro
11.
Disassemble the outer ventilation hood to enable access to the fastening
holes:
•
Fig. 16a. For the models VENTO V50-1. Remove the front part of the outer
ventilation hood.
•
Fig. 16b - for VENTO V50-1 S. Loosen these 5 screws and take off the front
part of the outer ventilation hood.
Fig. 16a.
Fig. 18.
Fig. 19.
Fig. 16b.
12.
Fix the back part of the outer hood on the wall using the screws 4x40 from
the delivery set.
13.
Install the front part of the outer ventilation hood:
14.
Install the control panel SEA-T12 with a power unit inside a prepared hole
in the wall, see Fig. 17. During selection of the control panel mounting place
consider the supplied cable length. A longer cable may be used if required, of
Unitronic LIYY UL CSA 5xAWG/7 (5x0.25) type.
15.
Uplift gently the buttons and take the buttons and the plug from the
control panel SEA-T12 off, Fig. 18.
16.
Unlatch and remove the frame of the control and power unit, Fig. 19.
140 mm
Ø 68 mm
2 holes
SEA
А
А
70 mm
48 mm
48 mm
70 mm
R35
2 radii
SEA-Т12
Fig. 17.