vento expert (Duo) a50(30)-1 Pro/Pro3

5

THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED 

PHYSICAL, MENTAL, OR SENSORY CAPACITIES, OR THOSE WITHOUT THE APPROPRIATE 

TRAINING.

THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED 

PERSONNEL AFTER THE APPROPRIATE BRIEFING.

THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED 

ACCESS BY UNATTENDED CHILDREN.

PURPOSE

The ventilator is designed to ensure continuous mechanical air exchange in flats, cottages, hotels, cafés and other domestic and public 
premises. The ventilator is equipped with a regenerator that enables supply of fresh filtered air heated by means of extract air heat energy 
recovery. The ventilator is designed for wall flush mounting.

The unit is rated for continuous operation without disconnection from the power supply.
Transported air must not contain any flammable or explosive mixtures, evaporation of chemicals, sticky substances, fibrous materials, 
coarse dust, soot and oil particles or environments favourable for the formation of hazardous substances (toxic substances, dust, 
pathogenic germs).

Name

Vento Expert A50-1 Pro/Pro3

Vento Expert Duo A30-1 Pro

Indoor unit of the ventilator

1 pc.

1 pc.

Air duct

1 pc.

1 pc.

Air flow distributor

3-6 pcs.

Sound-absorbing material

1 pc.

Assembled cartridge

1 pc.

1 pc.

Outer ventilation hood

1 pc.

1 pc.

Remote control

1 pc.

1 pc.

Cardboard template

1 pc.

1 pc.

Fastening set

2 packs

2 packs

Foam wedges

1 set

1 set

User's manual

1 pc.

1 pc.

Mounting hood installation instruction

1 pc.

1 pc.

Packing box

1 pc.

1 pc.

Vento

Expert A 50 -1 L S10 Pro

Automation availability

Pro – controls and control unit are included in the delivery set
Pro3 – model without automatic shutters, with manual airflow blocking

Ventilation hood model
Air duct length

_ – 500 mm
L – 700 mm
L035 – 350 mm
L10 – 1000 mm

Front panel modification

1 – flat front panel

Rated air flow [m3/h]
Air duct cross section

A – round

Ventilator series

Expert is a series of reversible ventilators with a unidirectional air flow.
Expert Duo is a series of reversible ventilators with a countercurrent air flow.

DELIVERY SET

DESIGNATION KEY

Summary of Contents for 4058448022999

Page 1: ...Single room reversible energy recovery ventilator USER S MANUAL EN Vento Expert A50 1 Pro Vento Expert A50 1 Pro3 Vento Expert Duo A30 1 Pro ...

Page 2: ...e Vento Expert Duo A50 30 1 Pro Pro3 unit and all its modifications Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country The information in this user s manual is correct at the time of...

Page 3: ... the entire service life of the unit While transferring the unit control the user s manual must be turned over to the receiving operator UNIT INSTALLATION AND OPERATION SAFETY PRECAUTIONS Disconnect the unit from power mains prior to any installation operations Unpack the unit with care The unit must be grounded While installing the unit follow the safety regulations specific to the use of electri...

Page 4: ...stances in close proximity to the unit When the unit generates unusual sounds odour or emits smoke disconnect it from power supply and contact the Seller Do not open the unit during operation Do not direct the air flow produced by the unit towards open flame or ignition sources Do not block the air duct when the unit is switched on In case of continuous operation of the unit periodically check the...

Page 5: ...rous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dust pathogenic germs Name Vento Expert A50 1 Pro Pro3 Vento Expert Duo A30 1 Pro Indoor unit of the ventilator 1 pc 1 pc Air duct 1 pc 1 pc Air flow distributor 3 6 pcs Sound absorbing material 1 pc Assembled cartridge 1 pc 1 pc Outer ventilation hood 1 pc 1 pc R...

Page 6: ...l are indicated on the unit casing The air duct length depends on the unit model refer to the Designation Key section page 6 The supplied ventilation hood model depends on the ventilator model The overall dimensions of the outer ventilation hood the required outside protrusion length of the air duct A and the mounting sequence of the hood are stated in its mounting instruction The overall dimensio...

Page 7: ...tor Frontpartoftheindoorunitwithafrontpanel Fulfils the decorative function The design enables to shut off the air duct in case of an extended downtime of the ventilator The front part of the Vento Expert Duo unit is used for air filtration Back part of the indoor unit The unit includes a circuit control board and basic controls located on the side part Back part of the indoor unit The unit includ...

Page 8: ...e of the ventilator fans operates in the air extract mode and the other one operates in the air supply mode at a set speed The fans do not change their rotation direction Boost if the sensor is actuated the ventilator follows one of two functioning algorithms set via the DIP switch during the ventilator setup For details see page 14 The DIP switch is set to OFF the ventilator runs in the extract m...

Page 9: ...500 min 500 min 500 2 Install the air duct in the wall and fix it with mounting foam The air duct end must protrude for the distance that enables installation of the outer ventilation hood see the User s manual for the outer ventilation hood A min 3 mm Fill the gaps between the wall and the hole with a mounting foam Foam wedge Install the air duct in the wall in such a way so it protrudes from the...

Page 10: ...the master plate 4 Unlatch and detach the front part of the indoor unit from its back part The thermal actuator rod must be in lower position when installing the front panel of the Vento Expert A50 1 Pro unit 5 Fix the back part of the indoor unit on the wall with the screws supplied with the mounting kit of the ventilator Remove the two retaining screws from the left transparent cover to enable a...

Page 11: ...from the outside Roll the layer of the sound absorbing material to match the air duct diameter The protecting paper layer must be outside Insert the sound absorbing roll into the cartridge against stop Make a mark at the end of the air duct remove the material and cut the roll as marked After that insert the ready roll into the air duct 9 Install the sectional air flow separators from the outside ...

Page 12: ... only The actual conductor cross section selection must be based on its type maximum permissible heating insulation length and installation method Use copper wires for all the electric connections Connect the ventilator to power mains in compliance with the wiring diagram EXTERNAL CONNECTIONS DIAGRAM The ventilator design enables connecting external devices with a normally open contact NO contact ...

Page 13: ...Slave 1 Slave N N L N L In Gnd Gnd Out NO1 NO2 12V N L N L In Gnd Gnd Out NO1 NO2 12V N L N L In Gnd Gnd Out NO1 NO2 12V N L Power input АС 100 240V 50 60 Hz to the next ventilator to the next ventilator to the next ventilator VENTILATOR SET UP ON DIP 1 2 3 4 5 6 7 8 Open the rubber plug DIP switch under the plug Prior to operating the ventilator set it up using the DIP switch It is located on the...

Page 14: ...er elapsing of the time set on the turn on delay timer Humidity control is disabled Set value 40 Set value 50 Set value 60 Set value 70 Set value 80 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 Delay timer During activation of the humidity sensor or any other external device the ventilator switches to higher speed After normalization of the indoor humidity level or any other air parameters the ventilator w...

Page 15: ...or for emergency shutdown of the unit Permanent glowing of the Alarm indicator of the Master unit indicates an alarm in the network of the connected ventilation units Its blinking indicates shutdown of a specific ventilation unit in the network In case of an emergency shutdown of a Vento Expert A50 1 Pro Pro3 unit in the network the defective ventilation unit is marked with the blinking Alarm indi...

Page 16: ...Vento Expert Duo A30 1 Pro Press the side tabs to detach the front part of the indoor unit from its back part and close the air duct Then gently unlatch and remove the front panel from the front part of the indoor unit Remove the air flow separator by pulling one of the side clamps Install the front part of the indoor unit into place Install the front panel on the front part of the indoor unit and...

Page 17: ...l Remove the filters for cleaning Perform all the above operations in the reverse order after cleaning Vento Expert A50 1 Pro Pro3 1 Press the latches on the side of the indoor control unit to take off the front part Please make sure the louver actuator rod is in lower position during re installation of the front panel If the thermal actuator rod is up please wait for about 2 minutes until it goes...

Page 18: ...ery clean the regenerator with a vacuum cleaner at least once a year To reset the filter timer connect the ventilator to the power supply using the circuit breaker before installing the front panel of the indoor unit into its place After that turn the DIP switch No 8 on for not less than 3 seconds and then turn it off For details see page 14 If necessary the remote control battery may be replaced ...

Page 19: ... after transportation at low temperatures allow the unit to warm up at operating temperature for at least 3 4 hours TROUBLESHOOTING POSSIBLE REASONS ANDTROUBLESHOOTING Problem Possible reasons Troubleshooting When switching on the ventilator the fan does not start No power supply Make sure the power supply line is connected correctly otherwise troubleshoot the connection error The motor is jammed ...

Page 20: ...ual Contact the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the u...

Page 21: ...www blaubergventilatoren de Vento Expert Duo A50 30 1 Pro Pro3 21 ...

Page 22: ...www blaubergventilatoren de Vento Expert Duo A50 30 1 Pro Pro3 22 ...

Page 23: ... INSTALLATION CERTIFICATE The Vento Expert ________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all the applicable local and national construction electrical and technical...

Page 24: ...www blaubergventilatoren de B139EN 05 ...