background image

www.blaubergventilatoren.de

vento expert a50c3-1 S8 W v.2

19

WIRELESS CONNECTION OF SEVERAL VENTILATION UNITS

WI-FI PARAMETER SETUP

Master unit via Wi-Fi. The Master unit is operated by means of a mobile device, the remote control or the touch buttons on the unit 
casing. The control signal is automatically transferred to the connected Slave units. In this mode the unit responds to a signal from sensors 
(humidity sensor, external digital sensor, external analogue sensor 0-10 V) and changes its operation mode respectively.

Slave

The unit acts as a driven unit in the network. The Slave unit responds to a signal from the master ventilator only. Any other signals from 
other controls are ignored. In this mode the ventilators also ignore the sensor signals. In case of communication loss with the Master unit 
above 20 seconds, the unit switches to Standby mode.

Timer operation

The ventilators respond to sensor feedback only in the Master mode.
In case of actuation of any sensors, all the connected ventilators go to maximum speed.
Wi-Fi parameters are only set on Master units. To set up ventilator Wi-Fi parameters via the mobile app, go to 

Menu -> Connection -> 

WI-FI setup

.

Press the 

Receive

 button to display the current Wi-Fi settings. 

Select one of the Wi-Fi operation modes:

Access Point

: access point mode without a home router. 

Select the desired security level for the 

Access point

 mode:

• 

Open

 – open Wi-Fi network without a password.

• 

WPA PSK

: password-protected. Encryption technology, using the WPA protocol, which does not 

guarantee complete security.

• 

WPA2 PSK

: password-protected. The type of data encryption for modern network devices.

• 

WPA/WPA2 PSK

: password-protected (recommended). Combined technology that activates WPA and 

WPA2 and at the same time provides maximum compatibility with any of your devices.

Enter your access point password and press the 

Apply

 button.

Client

 – the unit operates on the home router network.

Enter the home router details and the IP address type for the client mode.
•  Enter the name of the Wi-Fi home router access point.
•  Enter the password for the Wi-Fi home router access point.
Select IP address type:

DHCP

: the IP address is set up automatically upon connection to the home router (recommended).

Static

: enables manual entry of the desired IP address, subnet mask and default gateway. 

These settings are recommended for expert users only. 
Select this IP address type at your own risk.
Then press the 

Apply

 button.

Wiring diagram 1

Connection of up to 8 Slave units or mobile devices to the Master unit with its own wireless access point.

Summary of Contents for 4058448060311

Page 1: ...Single room reversible energy recovery ventilator USER S MANUAL EN Vento Expert A50C3 1 S8 W V 2 ...

Page 2: ...t design and operating principle 6 Installation and set up 8 Connection to power mains and control 11 Technical maintenance 24 Storage and transportation regulations 26 Manufacturer s warranty 27 Certificate of acceptance 31 Seller information 31 Installation certificate 31 Warranty card 31 This user s manual is a main operating document intended for technical maintenance and operating staff The m...

Page 3: ...water Protect the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour or emits smoke disconnect it from power supply and contact the Seller Do not open ...

Page 4: ...n any flammable or explosive mixtures evaporation of chemicals sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dust pathogenic germs DELIVERY SET Name Number Indoor unit of the ventilator 1 pc Air duct 1 pc Sound absorbing material 1 pc Assembled cartridge 1 pc Outer ventilation hood 1 pc R...

Page 5: ...kness is above the minimum Wall thickness is minimal Outer ventilation hood Front panel Front panel Cartridge Cartridge Air duct length Wall thickness Outer ventilation hood A protruding part of the air duct on the outer wall Depends on the selected ventilation hood type L cartridge length Depends on the cartridge modification The supplied air duct length and the supplied ventilation hood model de...

Page 6: ...eration VENTILATOR DESIGN The ventilator consists of an indoor unit with a decorative front panel a cartridge an air duct with a sound absorbing layer and an outer ventilation hood The cartridge is a basic functioning part of the ventilator The cartridge consists of the fans the regenerator and two filters that ensure rough air filtration and prevent ingress of dust and foreign objects into the he...

Page 7: ... is extracted from the room and flows through the ceramic regenerator which gradually absorbs heat and humidity In 70 seconds as the ceramic regenerator gets warmed the ventilator is switched to air supply mode Cycle II Fresh intake air from outside flows through the ceramic regenerator absorbs accumulated moisture and is heated up to the room temperature In 70 seconds as the ceramic regenerator g...

Page 8: ... duct in the wall For ease of installation use the foam wedges included in the delivery set The air duct end must protrude for the distance A that enables installation of an outer ventilation hood Distance A is stated in the installation instruction for the ventilation hood A min 3 mm Fill the gaps between the air duct and the hole with mounting foam Polystyrene wedge Install the air duct with the...

Page 9: ...rs 4 holes 4 Unlatch and detach the front part of the indoor unit from its back part ATTENTION Prior to mounting the front panel make sure that the thermal actuator rod is in the lowest position Blinking of the white LED indicator means that the thermal actuator is not in the low position 5 Fix the back part of the indoor unit on the wall with the screws supplied with the mounting kit of the venti...

Page 10: ...stall the front part of the indoor unit 9 Insert the sound absorbing layer in the air duct Roll the layer of the sound absorbing material to match the air duct diameter The protecting paper layer must be outside Insert the sound absorbing roll into the cartridge against stop Make a mark at the end of the air duct remove the material and cut the roll as marked Insert the ready sound absorbing roll ...

Page 11: ...wer mains via the terminal block installed in the control board in compliance with the wiring diagram and terminal designation Connect the ventilator to power mains through an automatic circuit breaker with magnetic trip integrated into the home wiring system The tripping current of the circuit breaker is selected based on the electrical characteristics shown on the label of the fan casing The ven...

Page 12: ...lave unit hereinafter referred to as Slave unit Standby mode setup 2 OFF the ventilator is switched off in the Standby mode 2 ON the ventilator operates at Speed I in the Standby mode SetupofairflowdirectioninVentilationmodewithrunningventilatorsforVentoExpert 3 OFF operation in air extraction mode 3 ON operation in air supply mode Restore factory default settings 4 OFF standard operation of the u...

Page 13: ...the ventilation unit in the air supply mode This mode may be activated only via the mobile application Filter 90 days after installation of the cartridge the filter replacement indicator starts glowing In this case clean or replace the filters see the Technical maintenance section After replacement of the filters reset the timer using the mobile application or by pressing and holding the button on...

Page 14: ...or operates in permanent air supply or air extraction mode at set speed The fan rotation direction depends on the position of the DIP switch 3 Timer control buttons Party mode the timer activates operation of the unit at Speed III for a set time period 4 hours by default The timer setting may be changed during setup of the unit on mobile device Night mode the timer activates operation of the venti...

Page 15: ... a Wi Fi access point FAN 16 characters of the ID number indicated on the control board of the ventilator Wi Fi access point password 11111111 1 2 4 5 6 8 7 3 Enter the Blauberg Vento V 2 app and create a new connection by following the steps below 1 Enter the app menu 2 Select Connection At home 3 If the mobile device is connected to the Wi Fi access point of the unit without a router select the ...

Page 16: ...to the ventilator Home connection or connection via a cloud server through Internet respectively Speed III activation indicator It goes on after activation of any sensor Whenthismodeisactivated alltheothermodesaredeactivated Uponelapseoftheturn offdelaytimercountdown 30 minutes by default the ventilation unit reverts to the previous mode Press Power to deactivate this operation mode Humidity indic...

Page 17: ...rs Humidity sensor activation of the humidity sensor When the indoor humidity exceeds the set point the unit switches to Speed III When the humidity level drops below the threshold value the Boost turn off delay timer is activated When the timer elapses the ventilator reverts to the previous speed setting 0 10 V sensor activation of the external analogue sensor 0 10 V When a 0 10 V control signal ...

Page 18: ...he Slave units If so replace the filters on all the ventilators on the network Upon filter timer reset the filter replacement warning is disabled on all the connected ventilators The filter timer can also be reset by means of the button on the indoor unit see page 14 To restore the factory settings via the mobile app go to Menu Settings Factory settings Then press the Reset to factory settings but...

Page 19: ...he Receive button to display the current Wi Fi settings Select one of the Wi Fi operation modes Access Point access point mode without a home router Select the desired security level for the Access point mode Open open Wi Fi network without a password WPA PSK password protected Encryption technology using the WPA protocol which does not guarantee complete security WPA2 PSK password protected The t...

Page 20: ...d by the technical characteristics of the router If the Wi Fi router capacity is not enough to connect a required number of the units you may use an extra wireless access point to connect the other the unit Several Master units can optionally be connected to the network for arranging a zone control To connect a master and a slave ventilator set the DIP switches on the units accordingly see page 13...

Page 21: ...n button on the ventilator casing for 5 seconds until the beep and blinking of all the LED lights The ventilator will continue in this mode for 3 minutes and then automatically revert to the previous settings To exit the Setup mode immediately press and hold the Ventilation button on the ventilator casing once again for 5 seconds until the beep and shutdown of all the LED lights In this mode the f...

Page 22: ...spective button if necessary 5 Enter a ventilator name of choice the ventilator ID as stated on the control circuit board and the unit password 1111 by default 6 Confirm the updated details To log into the account via the mobile app go to Menu Connection Through cloud server Then enter the login and password and press the Log in button The ventilators can be controlled using the mobile app via a c...

Page 23: ...utomatically The unit functionality is not changed To open the air duct pull the front panel while holding the special recesses The fan starts operating according to the actual speed setting Air duct blocking Air duct opening The front panel incorporates an operating LED indicator During the dark time the indicator light intensity drops down ...

Page 24: ...e of the indoor control unit to take off the front part Please make sure the thermal actuator rod is in lower position during re installation of the front panel If the thermal actuator rod is up please wait for about 2 minutes until it goes down Warning Prior to mounting the front panel make sure that the ther mal rod is in the low position and the indicator of the circuit board glows 2 Disconnect...

Page 25: ...e filter rated service life is 3 years Some dust may accumulate on the heat exchanger block even in case of regular maintenance of the filters Clean the regenerator regularly to ensure its high heat recovery efficiency Vacuum clean the regenerator not less than once a year 4 Replacement of the remote control battery if necessary In case of a long operation of the remote control the battery must be...

Page 26: ...r up after transportation at low temperatures allow the unit to warm up at operating temperature for at least 3 4 hours POSSIBLE REASONS AND TROUBLESHOOTING Problem Possible reasons Troubleshooting When switching on the ventilator the fan does not start No power supply Make sure the power supply line is connected correctly otherwise troubleshoot the connection error The motor is jammed the impelle...

Page 27: ...l Contact the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the use...

Page 28: ...www blaubergventilatoren de Vento Expert A50C3 1 S8 W V 2 28 ...

Page 29: ...www blaubergventilatoren de Vento Expert A50C3 1 S8 W V 2 29 ...

Page 30: ...www blaubergventilatoren de Vento Expert A50C3 1 S8 W V 2 30 ...

Page 31: ...ed and accepted Customer s Signature The Vento Expert _________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all the applicable local and national construction electrical a...

Page 32: ...www blaubergventilatoren de B133 6EN 01 ...

Reviews: