background image

www.blaubergventilatoren.de

3

Box-D

BLAUBERG Ventilatoren GmbH

 is happy to off er your attention the 

exhaust centrifugal fan 

Box-D

INTRODUCTION

The present operation manual contains a technical description, technical 

data sheets, operation and mounting guidelines, safety precautions and 
warnings for safe and correct operation of the fan.  

Read carefully and understand the operation manual, especially the safety 

requirements, before the appliance mounting and start up.

Keep the operation manual available as long as you use the appliance.

GENERAL

The exhaust centrifugal fan Box-D is designed for exhaust ventilation of 

various premises, heated in winter. 

The fans are not a ready to use product but a component part of a 

ventilation network. The fans are designed for ceiling mounting and for 
connection to Ø 100 or 200 mm air ducts, depending on the model.

The fans are allowed for operation only after fi nal mounting that includes 

installation of protecting devices in compliance with DIN EN ISO 13875 (DIN 
EN ISO 12100) as well as other construction safety equipment. 

Design of the fans is regularly improved, so some models can slightly 

diff er from those ones described in this operation manual.

SAFETY RULES

All operations related to the appliance electrical connections, servicing and 

repair works are allowed only after the appliance disconnection from power 
mains.  

The unit is rated as a Class I electrical appliance.
All mounting and servicing operations are allowed by duly qualifi ed 

personnel. 

Please follow the safety regulations and working instructions (DIN EN 50 

110, IEC 364).

Make sure the impeller and the casing are not damaged before connecting 

the appliance to power mains. The casing internals must be free of any 
foreign objects which can damage the impeller blades or the motor.

The appliance maintenance and repair are allowed only after power cut-off  

and full stop of the rotating parts.

Misuse of the appliance or any unauthorized modifi cation are not allowed. 
The appliance is designed for connection to power mains in compliance 

with the "Technical Data" section. 

The appliance is rated for permanent operation.
Take steps to prevent ingress of smoke, carbon monoxide and other 

combustion products into the room through open chimney fl ues or other 
fi re-protection devices. Suffi

  cient air supply must be provided for proper 

combustion and exhaust of gases through the chimney or fuel burning 
equipment to prevent back drafting.  The maximum permitted pressure 
diff erence per living appliances is 4 Pa.

The transported air must not contain any dust or other solid impurities, as 

well as sticky substances and fi brous materials.

The appliance is not rated for operation in a fl ammable or explosive 

medium. 

Fulfi l the operation manual requirements to ensure a trouble-free and long 

service life of the appliance. 

TRANSPORTATION AND STORAGE RULES

Transportation of the appliance is allowed by any vehicle provided the 

appliance is transported in the original package and is protected against 
weather and mechanical damages. 

Use hoist machinery for handling and transportation to prevent 

possible mechanical damages of the appliance. Fulfi l the requirements for 
transportation of the specifi ed cargo type during cargo-handling operations. 

Store the appliance in a dry and cool place in the original packing.
The storage environment must not be subjected to any aggressive and/

or chemical evaporations, admixtures, foreign objects that may provoke 
corrosion and damage connection tightness. 

Store the appliance in an environment with minimized risk of mechanical 

damages, temperature and humidity fl uctuations. 

Do not expose the appliance to the temperatures below  +5 °C and above  

+40 °C .

Connection of the appliance to power supply is allowed after the 

appliance has been kept indoor for minimum two hours.

MANUFACTURER'S WARRANTY

The appliance complies with the requirements according to the EU norms 

and directives, to the relevant EU-Low Voltage Equipment Directives, EU-
Directives on Electromagnetic Compatibility. 

We hereby declare that the appliance complies with the essential protection 

requirements of Electromagnetic Council Directive 2004/108/EC, 89/336/EEC 
and Low Voltage Directive 2006/95/EC, 73/23/EEC and CE-marking Directive 
93/68/EEC on the approximation of the laws of the Member States relating 
to electromagnetic compatibility, which relate to electrical appliances used 
in set voltage classes. 

The manufacturer hereby warrants normal operation of the appliance 

over the period of two years from the retail sale date provided observance 
of the installation and operation regulations. In case of a failure due to a 
manufacturing fault during the warranty period the consumer has the right 
to exchange it.

The replacement is off ered by the Seller. 
In case of no confi rmation of the sale date, the warranty period is calculated 

from the manufacturing date.

The MANUFACTURER is not responsible for any damage resulting from any 

misuse of or gross mechanical interference with the appliance.

The MANUFACTURER is not responsible for the damages resulted due to 

the use of  third party equipment or to third party equipment.

 

                 

WARNING

Do not dispose in domestic waste. 
The appliance contains in part ma-

terials that can be recycled and in part 

substances that should not end up as domestic 
waste. 

Dispose of the appliance once it has reached the 

end of its working life according to the regulations 
valid in your country.

  

 

WARNING 

The appliance is not allowed for use by 

children and persons with reduced phys-

ical, mental or sensory capacities, without proper 
practical experience or expertise, unless they are 
controlled or instructed on the product operation 
by the person(s) responsible for their safety. 

Supervise the children and do not let them play 

with the product.

!

Summary of Contents for Box-D 100

Page 1: ...Box D EXHAUST CENTRIFUGAL FAN OPERATION MANUAL EN...

Page 2: ...and storage rules 3 Manufacturer s warranty 3 Design 4 Delivery set 4 Technical data 5 Mounting and operation guidelines 5 Mounting sequence 6 Connection to power mains 7 Technical maintenance 8 Troub...

Page 3: ...d long service life of the appliance TRANSPORTATION AND STORAGE RULES Transportation of the appliance is allowed by any vehicle provided the appliance is transported in the original package and is pro...

Page 4: ...duct from ingress of contaminants The fan has a spring loaded damper for back drafting prevention The connecting spigot is equipped with a rubber seal The fan is fixed using the mounting brackets fro...

Page 5: ...tarting mounting read carefully the operation manual check the fan for possible transport damages Follow the safety regulations during the fan start up and operation Model Dimensions mm Weight kg D B...

Page 6: ...d the filter Remove the screw and take off the grille 3 Mark and drill the holes on the mounting surface for the dowels to fix the ceiling brackets 280 mm 4 Screw the mounting brackets to the ceiling...

Page 7: ...ox Cut power supply to the fan off by turning the automatic electric switch QF to OFF position Take steps to prevent activation of the automatic switch prior to finishing mounting CONNECTION TO POWER...

Page 8: ...nce consists in the periodic cleaning of the fan surfaces The filter should be replaced as needed but at least once a month The impeller requires thorough cleaning once in 6 months Cleaning procedure...

Page 9: ...led impeller blades Remove the motor jam clean the impeller blades Automatic switch tripping Short circuit in power grid Turn the fan off and contact the seller for troubleshooting Noise vibration The...

Page 10: ...imation of the laws of the Member States relating to electromagnetic compatibility This certificate is issued following test carried out on samples of the product referred to above Approval mark Manuf...

Page 11: ...___________________________ _______________________________________________________________________________________ ____________________________________________________________________________________...

Page 12: ...www blaubergventilatoren de Box D v 3 2 EN...

Reviews: