Freshbox 100

Minimum distances from the unit to the surfaces

min 300 mm

min 11 13/16"

min 300 mm

min 11 13/16"

2 holes Ø 130 mm (5 

1

/

8

") hole for Ø 100 mm (3 

15

/

16

")

Fill the gaps between the wall and 

the air ducts with a mounting foam

4 holes (Ø 8 (

5

/

16

") 

and 90 mm (3 9/16") deep) 

in the wall made using 

a mounting template

Power cable entry

Power cable entry

2 holes Ø 130 mm (5 1/8") hole for Ø 100 mm (3 15/16")

Fill the gaps between the wall and 

the air ducts with a mounting foam

4 holes (Ø 8 (5/16") 

and 90 mm (3 9/16") deep) 

in the wall made using 

a mounting template

416.5 mm

16 

3/

8"

647 mm 25 

1/2

"

205 mm

1/16

"

162 mm

3/

8"

468.5 mm

18 

7/

16"

102.5 mm

1/16

"

76 mm

3"

400 mm

15 3/4"

73.5 mm

2 7/8"

547 mm

21 9/16"

91 mm

3 9/16"

230 mm

9 1/16"

170 mm

6 11/16"

188.5 mm

7 7/16"

158.5 mm

6 1/4"

77 mm

3"

ADDITIONAL HOLE!

DRILL UPON CUSTOMER’S REQUEST ONLY!

Ø 130 mm (5 1/8") hole for Ø 100 mm (3 15/16") air ductFill the 

gaps between the wall and 

the air ducts with a mounting foam

ADDITIONAL HOLE!

DRILL UPON CUSTOMER’S REQUEST ONLY!

Ø 130 mm (5 

1

/

8

") hole for Ø 100 mm (3 

15

/

16

") air duct

Fill the gaps between the wall and the air ducts with a 

mounting foam

Mounting template

Summary of Contents for Freshbox 100

Page 1: ...05 e mail info blauberg us INSTALLATION GUIDE Toolsrequired Pencil ScotchTape Saw Mountingfoam Drill Ø6mm Screwdriver Dowel4 pcs Screws4 pcs AIR HANDLING UNIT WITH HEAT RECOVERY FRESHBOX 100 400 mm 15 3 4 200 mm 7 7 8 257 mm 10 1 8 590 mm 23 1 4 690 mm 27 3 16 Ø 100 mm Ø 3 15 16 3 holes ...

Page 2: ...een the wall and the air ducts with a mounting foam 4 holes Ø 8 5 16 and 90 mm 3 9 16 deep in the wall made using a mounting template 416 5 mm 16 3 8 647 mm 25 1 2 205 mm 8 1 16 162 mm 6 3 8 468 5 mm 18 7 16 102 5 mm 4 1 16 76 mm 3 400 mm 15 3 4 73 5 mm 2 7 8 547 mm 21 9 16 91 mm 3 9 16 230 mm 9 1 16 170 mm 6 11 16 188 5 mm 7 7 16 158 5 mm 6 1 4 77 mm 3 ADDITIONAL HOLE DRILL UPON CUSTOMER S REQUES...

Page 3: ...the unit mounting place 2 Remove the mounting template and drill two through holes Ø 105 mm Ø 4 1 8 for round air ducts When mounting the unit with an additional extract spigot prepare a hole in the wall for a connecting bend and for laying of a rectangular air duct A connecting bend rectangular and round air ducts are available separately Drill holes Ø 8 mm Ø 5 16 90 mm 3 9 16 deep to mount the u...

Page 4: ...l aligning the mounting template hole with a round end of the connecting bend Connect a rectangular duct to the connecting bend 4 Fill the spaces between the air ducts and the wall with a mounting foam through the specially designed holes in the mounting template Wait till a mounting foam hardens then take off the mounting template and remove the foam excess Cut off the protruding air duct parts t...

Page 5: ...heat exchanger Remove the magnetic plug from the exhaust grille if an additional extract spigot is not installed 7 Fix the unit on the wall using the supplied screws and expansion anchors Install the heat exchanger back and close the unit door Cut a part of the drain pipe protruding outside to a length not more than 10 mm 3 8 Fix the outer hood on the outer wall of the building see the ventilation...

Page 6: ...e not included in the scope of delivery Connection of additional external control contacts is implemented in the control unit For accessing the control unit open the unit door release the screws fixing the shielding and remove it Connection of the automatic fire fighting system contact PK Upon connecting the automatic fire fighting system contact remove the jumper between the terminals 5 and 6 Rem...

Reviews: