CONTENTS

This user’s manual is a main operating document intended for technical, maintenance, and operating staff.
The manual contains information about the purpose, technical details, operating principle, design, and installation of the KOMFORT ERV D 
unit (-s) and all of its (their) modifications.
Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to 
work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country.
The information in this user’s manual is correct at the time of the document’s preparation.
The Company reserves the right to modify the technical characteristics, design, or configuration of its products at any time in order to 
incorporate the latest technological developments.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means in any information 
search system or translated into any language in any form without the prior written permission of the Company.

SAFETY REQUIREMENTS

UNIT INSTALLATION AND OPERATION SAFETY PRECAUTIONS

•  Disconnect the unit from power mains prior 

to any installation operations.

•  Unpack the unit with care.

•  The unit must be grounded!

•  While installing the unit, follow the safety 

regulations specific to the use of electric 
tools.

•  Please read the user’s manual carefully prior to installing and operating the unit.
•  All user’s manual requirements as well as the provisions of all the applicable local and national construction, electrical, and technical 

norms and standards must be observed when installing and operating the unit.

•  The warnings contained in the user’s manual must be considered most seriously since they contain vital personal safety information.
•  Failure to follow the rules and safety precautions noted in this user’s manual may result in an injury or unit damage.
•  After a careful reading of the manual, keep it for the entire service life of the unit.
•  While transferring the unit control, the user’s manual must be turned over to the receiving operator.

Contents
Safety requirements ..................................................................................................................................................................... 2
Purpose ................................................................................................................................................................................................ 4
Delivery set ........................................................................................................................................................................................ 4
Designation key .............................................................................................................................................................................. 4
Technical data .................................................................................................................................................................................. 5
Design and operating principle ........................................................................................................................................... 7
Mounting and set-up .................................................................................................................................................................. 9
Connection to power mains .................................................................................................................................................. 10
Technical maintenance .............................................................................................................................................................. 11
Troubleshooting ............................................................................................................................................................................. 12
Storage and transportation regulations .......................................................................................................................... 12
Manufacturer’s warranty ........................................................................................................................................................... 13
Certificate of acceptance .......................................................................................................................................................... 14
Seller information .......................................................................................................................................................................... 14
Installation certificate .................................................................................................................................................................. 14
Warranty card ................................................................................................................................................................................... 14

Summary of Contents for KOMFORT ERV D150

Page 1: ...Energy recovery air handling unit USER S MANUAL EN KOMFORT ERV D150 KOMFORT ERV D250 KOMFORT ERV D350 ...

Page 2: ...D OPERATION SAFETY PRECAUTIONS Disconnect the unit from power mains prior to any installation operations Unpack the unit with care The unit must be grounded While installing the unit follow the safety regulations specific to the use of electric tools Please read the user s manual carefully prior to installing and operating the unit All user s manual requirements as well as the provisions of all th...

Page 3: ...h wet hands Do not carry out the installation and maintenance operations with wet hands Do not wash the unit with water Protect the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit...

Page 4: ...ation of chemicals sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dust pathogenic germs THE UNIT SHOULD NOT BE OPERATED BY CHILDREN OR PERSONS WITH REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPE...

Page 5: ...ntly being improved thus some models may be slightly different from those described in this manual Parameter KOMFORT ERV D150 KOMFORT ERV D250 KOMFORT ERV D350 Unit supply voltage 50 Hz V 1 230 Maximum unit power W 125 250 310 Maximum unit current A 0 6 1 1 1 4 Maximum flow rate m3 h 230 370 400 RPM min 1 2235 2400 2150 Sound pressure level at 3 m distance dBA 49 52 57 Transported air temperature ...

Page 6: ... A B A B Model Dimensions mm Ø D A A1 A2 B B1 B2 H H1 L L1 L2 L3 L4 L5 KOMFORT ERV D150 99 947 854 676 704 743 793 227 247 480 92 128 25 113 138 KOMFORT ERV D250 149 947 854 676 704 743 793 227 247 480 92 128 25 113 138 KOMFORT ERV D350 149 1117 1024 846 754 793 843 277 297 488 109 153 50 88 138 ...

Page 7: ...h the heat exchanger and is directed to the room with the supply fan Supply air is heated in the heat exchanger by transferring the heat energy of warm and humid extract air to the cold fresh air The air flows are fully separated while flowing through the heat exchanger Heat recovery minimizes heat losses which reduces the cost of space heating in the cold season The enthalpy heat exchanger provid...

Page 8: ...s 3 C After temperature increase the unit returns to the previous operation mode In the Defrosting mode the supply fan is turned off and the heat exchanger is warmed up with warm extract air flow To set the thermostat threshold value turn the control knob to the desired position The recommended thermostat operating temperature is 3 C factory setting EXTRACT AIR SUPPLY AIR INTAKE AIR EXHAUST AIR IN...

Page 9: ...ialist Before mounting make sure the casing does not contain any foreign objects e g foil paper The minimum distance between the unit and the ceiling should be at least 20 mm To attain the best performance of the unit and to minimise turbulence induced air pressure losses connect the straight air duct section to the spigots on both sides of the unit while mounting Minimum straight air duct length ...

Page 10: ...h an automatic circuit breaker built into the stationary wiring to open the electric circuit in case of overload or short circuit The circuit breaker installation place must provide quick access for emergency shutdown of the unit The trip current of the automatic circuit breaker QF must exceed the maximum current consumption of the unit refer to the technical data table The recommended trip curren...

Page 11: ...nozzle To replace the heat exchanger remove the inspection hatch located on the service panel and remove the contaminated heat exchanger Then install a new heat exchanger and an inspection hatch in the reverse order For a new heat exchanger contact the Seller 3 Fan maintenance once a year Even in case of regular maintenance of the filters some dust may accumulate inside the fans and reduce the fan...

Page 12: ...Store the unit in the manufacturer s original packaging box in a dry closed ventilated premise with temperature range from 5 C to 40 C and relative humidity up to 70 Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion insulation and sealing deformation Use suitable hoist machinery for handling and storage operations to prevent possible damage to the uni...

Page 13: ...anty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user s manual User s failure to ensure timely technical maintenance ...

Page 14: ...it delivery with the user s manual The warranty terms are acknowledged and accepted Customer s Signature The KOMFORT ERV D___________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of a...

Page 15: ...www blaubergventilatoren de KOMFORT ERV D 15 ...

Page 16: ...www blaubergventilatoren de B147EN 02 ...

Reviews: