www.blaubergventilatoren.de

KoMFort roto ec S2(e)200

3

•  Do not change the power cable length 

at your own discretion. Do not bend the 
power cable. Avoid damaging the power 
cable. Do not put any foreign objects on the 
power cable.

•  Do not lay the power cable of the unit in 

close proximity to heating equipment.

•  Do not use damaged equipment or cables 

when connecting the unit to power mains.

•  Do not operate the unit outside the 

temperature range stated in the user’s 
manual. Do not operate the unit in 
aggressive or explosive environments.

•  Do not touch the unit controls with wet 

hands. Do not carry out the installation and 
maintenance operations with wet hands.

•  Do not wash the unit with water. Protect 

the electric parts of the unit against ingress 
of water. 

•  Do not allow children to operate the unit.

•  Disconnect the unit from power mains prior 

to any technical  maintenance.

•  Do not store any explosive or highly 

flammable substances in close proximity to 
the unit.

•  When the unit generates unusual sounds, 

odour, or emits smoke, disconnect it from 
power supply and contact the Seller.

•  Do not open the unit during operation.

•  Do not direct the air flow produced by the 

unit towards open flame or ignition sources.

•  Do not block the air duct when the unit is 

switched on.

•  In case of continuous operation of the unit, 

periodically check the security of mounting.

•  Do not sit on the unit and avoid placing 

foreign objects on it.

•  Use the unit only for its intended purpose.

THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.

DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC  WASTE.

Summary of Contents for KOMFORT Roto EC S2 200

Page 1: ...Heat recovery air handling unit USER S MANUAL EN KOMFORT Roto EC S2 200 KOMFORT Roto EC S2E200...

Page 2: ...on of its products at any time in order to incorporate the latest technological developments No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by...

Page 3: ...r Protect the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any exp...

Page 4: ...ain any flammable or explosive mixtures evaporation of chemicals sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substa...

Page 5: ...ineral wool Filter extract G4 supply G4 F7 Connected air duct diameter mm 125 Weight kg 47 48 Heat recovery efficiency from 75 up to 92 Heat exchanger type rotary Heat exchanger material aluminium SEC...

Page 6: ...hood The kitchen hood must be equipped with an air damper to shut off the exhaust duct when the kitchen hood is not in use Unit design and operation principle service side view Intake filter Extract...

Page 7: ...able access to the fan the spigots may be covered with a protecting grille or other protecting device with mesh width not more than 12 5 mm While installing the unit ensure convenient access for subse...

Page 8: ...and install the humidity sensor into the mounting bracket on the exhaust duct wall Then connect the humidity sensor connector to the respective contact socket on the control unit 1 2 3 Contact socket...

Page 9: ...the unit for floor mounting Then undo the four self tapping screws and remove the plug in the bottom panel Lead the kitchen hood cable into the unit and connect it according to the external connection...

Page 10: ...on selection must be based on the maximum load current maximum conductor temperature depending on the wire type insulation length and installation method The external power input must be equipped with...

Page 11: ...connector for the kitchen hood X4 is located on the side wall of the unit It is necessary to lead the cable into the unit and connect it to the connector according to the wiring diagram For right han...

Page 12: ...and the control panel Phone cable up to 50 m AWG24 shielded cable up to 200 m External connections diagram of the KOMFORT Roto EC S2 E 200 S21 XS11 X1 1 C 2 NC 3 4 N 5 L Grey Black Yellow green Blue B...

Page 13: ...ncy regular cleaning is required To clean the heat exchanger remove it from the unit and clean the heat exchanger by using compressed air or a vacuum cleaner After cleaning re install the heat exchang...

Page 14: ...air duct pipe flanges Install anti vibration connectors SYSTEM ALARMS Fire alarm Emergency system shutdown on command from the fire alarm board This alarm interrupts the fan operation In case of such...

Page 15: ...air the user must provide the unit the user s manual with the purchase date stamp and the payment paperwork certifying the purchase The unit model must comply with the one stated in the user s manual...

Page 16: ...www blaubergventilatoren de KOMFORT Roto EC S2 E 200 16...

Page 17: ...www blaubergventilatoren de KOMFORT Roto EC S2 E 200 17...

Page 18: ...www blaubergventilatoren de KOMFORT Roto EC S2 E 200 18...

Page 19: ...__200 S___ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Installation Date...

Page 20: ...www blaubergventilatoren de B140 1EN 04...

Reviews: