background image

Primo

6

www.blaubergventilation.com.au

TECHNICAL DATA

The unit is designed for indoor application with the ambient temperature ranging from +1 °C up to +40 °C and relative humidity up to 
80 % at 25 °C. Ingress protection rating against access to hazardous parts and water ingress is IPX4.
The unit is rated as a class I electric appliance. The unit design is constantly being improved, thus some models may be slightly different 
from those described in this manual.

Overall dimensions of the unit [mm]

ød

ød

B

L

øD

C

A

B1

C1

Model

Dimensions [mm]

Weight 

[kg]

D

d

A

L

B

B1

C

C1

Primo 315

406

310

451

468

468

566

437

439

15

Primo 355

406

350

451

372

468

566

437

439

15

Primo 400

451

395

496

415

513

623

482

484

18.5

Summary of Contents for Primo 315

Page 1: ...Inline mixed flow fan USER S MANUAL EN Primo...

Page 2: ...certificate 13 Warranty card 13 This user s manual is a main operating document intended for technical maintenance and operating staff The manual contains information about purpose technical details...

Page 3: ...xplosive environment containing spirits gasoline insecticides etc Do not close or block the intake or extract vents in order to ensure the efficient air flow Do not sit on the unit and do not put obje...

Page 4: ...sely affect the safe operation of appliances burning gas or other fuels including those in other rooms due to back flow of combustion gases These gases can potentially result in carbon monoxide poison...

Page 5: ...explosive mixtures evaporation of chemicals sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances...

Page 6: ...s parts and water ingress is IPX4 The unit is rated as a class I electric appliance The unit design is constantly being improved thus some models may be slightly different from those described in this...

Page 7: ...a horizontal or vertical surface While installing the unit ensure convenient access for subsequent maintenance and repair Fasteners for fan mounting are not included in the delivery set and should be...

Page 8: ...nected the internal parts of the unit must be protected from ingress of foreign objects To prevent uncontrollable access to the fans the spigots may be covered with a protecting grille or other protec...

Page 9: ...g durable insulated and heat resistant conductors cables wires The actual wire cross section selection must be based on the maximum load current maximum conductor temperature depending on the wire typ...

Page 10: ...ions Disconnect the air ducts from the fan Clean the fans with a soft brush cloth vacuum cleaner or compressed air Do not use water aggressive solvents or sharp objects as they may damage the impeller...

Page 11: ...r up after transportation at low temperatures allow the unit to warm up at operating temperature for at least 3 4 hours TROUBLESHOOTING Problem Possible reasons Troubleshooting The fan s do es not get...

Page 12: ...ur goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement of the purchased product for a major failure of the product You are also entit...

Page 13: ...IFICATE The unit _____________________________________ is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation T...

Page 14: ...Primo 14 www blaubergventilation com au...

Page 15: ...www blaubergventilation com au Primo 15...

Page 16: ...www blaubergventilation com au BlaubergAustralasia208EN 06...

Reviews: