DESIGNATION KEY
Tower-SV-K2 - 630 - 6 D / 1.5 - K - U1 - 600/2 - Zn
Casing material and paint colour
_
– casing material: steel with powder painting, default colour: blue RAL5007
RALxxxx
– casing material: steel with powder coating, paint colour according to
RALxxxx
Zn
– casing material: galvanized steel
Fire resistance
600/2
– 600 °C, 2 hours.
Climatic modification (outdoor installation)
U1
– temperate climate
HL1
– cold climate
T1
– tropical climate
M1
– marine moderately cold climate
Options
K
– with a terminal box
S1
– built-in external switch
1.5
– motor power [kW]
Motor phase and operation modes
E
– single-phase across-the-line motor
EP
– single-phase motor with variable frequency start
D
– three-phase motor
DP
– three-phase motor with variable frequency start
6
– number of motor poles
630
– impeller size [mm]
Tower-SV-K2
– roof-mounted centrifugal smoke extraction fan with vertical air
discharge in an octagonal casing
www.blaubergventilatoren.de
tower-sV-k2