TECHNICAL DATA

The fans are rated for connection to 3~400 V/50 Hz power mains.
Both a direct connection to power mains and a connection via a frequency converter are possible.
The unit is rated as a Class I electrical appliance.
IP55 protection class.

Fan model

Installed capacit

y [kW

]

Cur

rent [

A]

Rat

ed RP

M [minˉ¹]

M

aximum air flo

[m

3/h]

Tower-SV-K2-315-2D/1.1-X-XX-600/2-XXX

1.10

2.55

2770

4250

Tower-SV-K2-355-4D/0.25-X-XX-600/2-XXX

0.25

0.83

1340

3200

Tower-SV-K2-355-2D/2.2-X-XX-600/2-XXX

2.2

4.69

2800

6500

Tower-SV-K2-400-6D/0.25-X-XX-600/2-XXX

0.25

1.02

880

3200

Tower-SV-K2-400-4D/0.55-X-XX-600/2-XXX

0.55

1.51

1360

4600

Tower-SV-K2-400-2D/4-X-XX-600/2-XXX

4.0

7.9

2840

9300

Tower-SV-K2-450-6D/0.25-X-XX-600/2-XXX

0.25

1.02

880

4250

Tower-SV-K2-450-4D/1.1-X-XX-600/2-XXX

1.10

2.75

1380

6800

Tower-SV-K2-450-2D/7.5-X-XX-600/2-XXX

7.50

14.3

2860

13500

Tower-SV-K2-500-8D/0.25-X-XX-600/2-XXX

0.25

1.36

680

4000

Tower-SV-K2-500-6D/0.55-X-XX-600/2-XXX

0.55

1.68

900

7000

Tower-SV-K2-500-4D/1.5-X-XX-600/2-XXX

1.5

3.55

1400

9500

Tower-SV-K2-560-8D/0.37-X-XX-600/2-XXX

0.37

1.76

690

6500

Tower-SV-K2-560-6D/0.75-X-XX-600/2-XXX

0.75

2.15

910

8500

Tower-SV-K2-560-4D/3-X-XX-600/2-XXX

3.0

6.48

1420

13000

Tower-SV-K2-630-8D/0.75-X-XX-600/2-XXX

0.75

2.64

700

9000

Tower-SV-K2-630-6D/1.5-X-XX-600/2-XXX

1.50

3.84

940

12500

Tower-SV-K2-630-4D/5.5-X-XX-600/2-XXX

5.50

11.3

1430

17500

Tower-SV-K2-710-8D/1.1-X-XX-600/2-XXX

1.1

3.46

700

13500

Tower-SV-K2-710-6D/2.2-X-XX-600/2-XXX

2.2

5.38

940

17500

Tower-SV-K2-710-4D/11-X-XX-600/2-XXX

11.0

22.3

1460

26500

Tower-SV-K2-800-8D/2.2-X-XX-600/2-XXX

2.2

5.8

710

19500

Tower-SV-K2-800-6D/4-X-XX-600/2-XXX

4.0

9.4

960

25000

Tower-SV-K2-800-4D/15-X-XX-600/2-XXX

15.0

30

1460

37500

Tower-SV-K2-900-10D/2.2-X-XX-600/2-XXX

2.2

8

590

21000

Tower-SV-K2-900-8D/4-X-XX-600/2-XXX

4.0

10.2

710

27500

Tower-SV-K2-900-6D/7.5-X-XX-600/2-XXX

7.5

16.5

960

36000

Tower-SV-K2-900-4D/30-X-XX-600/2-XXX

30.0

57.4

1470

53500

Tower-SV-K2-1000-10D/3-X-XX-600/2-XXX

3.0

9.5

590

30000

Tower-SV-K2-1000-8D/7.5-X-XX-600/2-XXX

7.5

17.7

710

38000

Tower-SV-K2-1000-6D/15-X-XX-600/2-XXX

15.0

31.5

950

52000

Tower-SV-K2-1120-10D/7.5-X-XX-600/2-XXX

7.5

21

590

47000

Tower-SV-K2-1120-8D/11-X-XX-600/2-XXX

11.0

25.1

730

55000

Tower-SV-K2-1120-8D/15-X-XX-600/2-XXX

15.0

34

730

62500

Tower-SV-K2-1120-6D/22-X-XX-600/2-XXX

22.0

44.6

950

71000

Tower-SV-K2-1120-6D/30-X-XX-600/2-XXX

30.0

59.3

960

80000

www.blaubergventilatoren.de

tower-sV-k2

6

Summary of Contents for Tower-SV-K2

Page 1: ...Roof mounted centrifugal smoke extraction fan USER S MANUAL EN Tower SV K2...

Page 2: ...al and national construction electrical and technical norms and standards must be observed when installing and operating the unit Disconnect the unit from the power supply prior to any connection serv...

Page 3: ...ck of experience and knowledge unless they have been given supervision or instruction concerning use of the unit by a person responsible for their safety Children should be supervised to ensure that t...

Page 4: ...nditions The fan handles smoke and air mixtures with temperatures up to 600 C for 60 minutes A characteristic feature of Tower SV K2 roof fans is an impeller with backward curved blades and an electri...

Page 5: ...U1 temperate climate HL1 cold climate T1 tropical climate M1 marine moderately cold climate Options K with a terminal box S1 built in external switch 1 5 motor power kW Motor phase and operation mode...

Page 6: ...0 75 2 15 910 8500 Tower SV K2 560 4D 3 X XX 600 2 XXX 3 0 6 48 1420 13000 Tower SV K2 630 8D 0 75 X XX 600 2 XXX 0 75 2 64 700 9000 Tower SV K2 630 6D 1 5 X XX 600 2 XXX 1 50 3 84 940 12500 Tower SV...

Page 7: ...Overall dimensions B A C H d 4 holes www blaubergventilatoren de Tower SV K2 7...

Page 8: ...0 75 K U1 600 2 Zn 1060 1010 750 1121 16 Tower SV K2 630 6D 1 5 K U1 600 2 Zn Tower SV K2 630 4D 5 5 K U1 600 2 Zn Tower SV K2 710 8D 1 1 K U1 600 2 Zn 1105 1180 980 1257 16 Tower SV K2 710 6D 2 2 K U...

Page 9: ...m the fan The fan delivery set may include a mounting frame available separately Install the mounting frame on a load carrying roof section true vertical inside a prepared opening The opening size mus...

Page 10: ...nal box located on the outer casing of the fan impeller located inside the support panel The motor with the impeller is rigidly fixed to the support panel Welded sheet steel construction The hub and c...

Page 11: ...gth and installation method Connection of the unit to the fixed power supply network must be carried out in accordance with the current regulations Caution The type of electrical connection is indicat...

Page 12: ...oth out the inrush the high startup torque has no adverse effects on the operation of the driven mechanism Soft start SS starting A soft starter gradually increases the voltage supplied to the motor f...

Page 13: ...ain relays and contactors go off and the supply generator shuts down Solution In the best case scenario an SS device may help reduce the in rush current to 250 of the motor rated current If this is in...

Page 14: ...OR TO COMMENCING ANY TECHNICAL MAINTENANCE PUT UP A PROHIBITORY SIGN ON THE FAN STARTING PANEL DO NOT SWITCH ON MEN AT WORK POSSIBLE MALFUNCTIONS AND THEIR ELIMINATION Problem Possible reasons Elimina...

Page 15: ...ace the fan with a unit of proper standard size The fan supplies less air than expected Wrong calculation of the ventilation network and wrong selection of the fan Re calculate the network parameters...

Page 16: ...ndling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanic...

Page 17: ...nation of faults in the unit operation to ensure its intended use by the user within the guaranteed period of operation The faults are eliminated by means of replacement or repair of the unit componen...

Page 18: ...www blaubergventilatoren de Tower SV K2 18...

Page 19: ...____________ is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Installation Date Si...

Page 20: ...www blaubergventilatoren de B81 1EN 01...

Reviews: