vento eco
5
The temperature in the room where the indoor unit of the ventilator is installed must be in the range from +1 ˚C to +40 ˚C with relative
humidity up to 65 % (no condensation build-up). If the conditions for using the ventilator are beyond the specified limits, turn off the
ventilator. Provide fresh air supply through windows.
The transported air temperature must be in the range from -20 ˚C to +40 ˚C.
The unit is rated as a class II electric appliance and must not be grounded.
Ingress Protection (IP) rating from solid objects and liquids IP24.
The unit design is constantly being improved, thus some models may be slightly different from those described in this manual.
A
Ø 160
Air duct length (wall thickness)
Outer ventilation hood
Indoor unit
215
60
250
160
160
80
80
55
55
OVERALL DIMENSIONS OF THE INDOOR UNIT [MM]
The air duct length depends on the unit model (refer to the designation key,
page 4).
Air duct length
VENTO Eco A50-4 Pro1
250(150*)-500 (10”(6”)-20”)
VENTO Eco2 A50-4 L Pro1
250 (150*)-700 (10”(6”)-28”)
* Minimum air duct length with the hood for thin walls AH-S
The ventilation hood model depends on the unit model. The overall dimensions
of the outer ventilation hood and the A distance are stated in the mounting
instruction for the outer hood.
The overall dimensions of the front panel see below.