www.blaubergventilatoren.de
Freshbox 100 WiFi
13
7. In emergency situations, the unit turns off and the
indicator flashes an alarm code.
Alarm code
Alarm description
4 long flashes
Outdoor sensor is missing
3 long, 1 short flash
Outdoor sensor short circuit
2 long, 1 short, 1 long flash
Sensor downstream of the heat exchanger is missing
2 long, 2 short flashes
Short circuit of the sensor downstream of the heat exchanger
1 long, 1 short, 2 long flashes
Exhaust sensor is missing
1 long, 1 short, 1 long, 1 short flash
Exhaust sensor short circuit
1 long, 2 short, 1 long flash
Connection error
1 long, 3 short flashes
Low battery
1 short, 1 long, 1 short, 1 long flash
Wi-Fi initialization error
You may find a detailed alarm description in a mobile application.
Remote control
Corresponds to switching
of the fifth speed
Corresponds to switching
of the third speed
Activation of the first speed
Unit on/off
Increase of the reheater
temperature setpoint
Decrease of the reheater
temperature setpoint
Reheater on/off
Week-scheduled
operation on/off
Timer on/off
Unit On/Off
Week-scheduled
operation on/off
Timer On/Off
Freshbox (E)-100 WiFi
Freshbox E1(E2)-100 WiFi
Corresponds to switching
of the fifth speed
Corresponds to switching
of the third speed
Activation of the first speed
Unit control via the application on the mobile device
The application Blauberg Freshbox is available for download at App Store
//itunes.apple.com/us/app/blauberg-freshbox/id1402506523
or Play Market
https://play.google.com/store/apps/details?id=com.embarcadero.BlaubergFRESHBOX
or via QR codes.
App Store download link
Play Market download link
Standard
IEFE 802,11, b/g/n
Frequency band [GHz]
2.4
Transmission power [mW] (dBm)
100(+20)
Network
DHCP
WLAN safety
WPA, WPA2
Wi-Fi technical data