DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY MAINTENANCE OPERATIONS!
Maintenance of the unit means regular cleaning of the unit surfaces of dust and cleaning and replacement of the filters. To access the
basic assembly units follow the steps:
Disconnect the socket connectors. Push the cable from the control panel aside to the wall and pull the cord from the cartridge to
remove it from the air duct. Remove the filters from the cartridge.
Clean the filters as they get contaminated, but not less than once in three months.
•
After expiry of the period set for the filter timer (factory setting 90 days) the filter replacement indicator
appears on the
control panel display.
•
Wash the filters and let those dry out completely. Then install the dry filters in the air duct.
•
Vacuum cleaning is allowed.
•
The filter rated service life is 3 years.
•
For new filters contact the Seller.
Even regular technical maintenance may not completely prevent dirt
accumulation on the regenerator and the fan.
•
Clean the regenerator regularly to ensure its high regeneration
efficiency.
•
Clean the regenerator with a vacuum cleaner at least once
a year.
TECHNICAL MAINTENANCE