RECOMMENDATIONS AND SUGGESTIONS

 

The Instructions for Use apply to several versions of this appliance. 
Accordingly, you may find descriptions of individual features that do not 
apply to your specific appliance. 

INSTALLATION 

The manufacturer will not be held liable for any damages resulting from
incorrect or improper installation.

• The minimum safety distance between the cooker top and the extractor hood

is 650 mm (some models can be installed at a lower height, please refer to
the paragraphs on working dimensions and installation).

• Check that the mains voltage corresponds to that indicated on the rating

plate fixed to the inside of the hood.

• For Class I appliances, check that the domestic power supply guarantees

adequate earthing.
Connect the extractor to the exhaust flue through a pipe of minimum
diameter 120 mm. The route of the flue must be as short as possible.

• Do not connect the extractor hood to exhaust ducts

carrying combustion fumes (boilers, fireplaces, etc.).

• If the extractor is used in conjunction with non-electrical

appliances (e.g. gas burning appliances), a sufficient
degree of aeration must be guaranteed in the room in
order to prevent the backflow of exhaust gas. The
kitchen must have an opening communicating directly
with the open air in order to guarantee the entry of clean air.

 

When the

cooker hood is used in conjunction with appliances supplied with energy
other than electric, the negative pressure in the room must not exceed 0,04
mbar to prevent fumes being drawn back into the room by the cooker hood.

• The air must not be discharged into a flue that is used for

exhausting fumes from appliances burning gas or other
fuels (not applicable to appliances that only discharge the
air back into the room).

• In the event of damage to the power cable, it must be

replaced by the manufacturer or by the technical service
department, in order to prevent any risks.

Summary of Contents for AP-5DA45450AU

Page 1: ...Instructions Manual ...

Page 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS CHARACTERISTICS INSTALLATION USE MAINTENANCE EN ...

Page 3: ...lue must be as short as possible Do not connect the extractor hood to exhaust ducts carrying combustion fumes boilers fireplaces etc If the extractor is used in conjunction with non electrical appliances e g gas burning appliances a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly wi...

Page 4: ... to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Do not flambè under the range hood risk of fire This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowled...

Page 5: ...avy usage Failure to carry out cleaning as indicated will result in a fire hazard Clean the hood using a damp cloth and a neutral liquid detergent The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this ...

Page 6: ...Body complete with Controls Light Blower Filters 2 1 Frame 8 1 Directioned grid 9 1 Reducer Flange ø 150 120 mm 10 1 Damper ø 150 mm Ref Q ty Installation Components 12a 10 Screws 12e 2 Screws 2 9 x 9 5 12f 6 Screws 2 9 x 6 5 Q ty Documentation 1 Instruction Manual 10 9 8 12e 12f 2 ...

Page 7: ...n opening in the bottom of the wall unit as shown Insert the hood until the side supports snap into place Fasten using the 10 screws 12a provided Lock in position by tightening the screws Vf from underneath the hood Open the suction panel by turning the specific knob Disconnect the panel from the hood canopy by sliding the fixing pin lever Remove grease filters Screw the Frame into place using the...

Page 8: ...ø120 RECIRCULATION VERSION AIR OUTLET Cut a hole ø 125 mm in any shelf that may be posi tioned over the hood Insert the reducer flange 9 on the hood body outlet Connect the flange to the outlet on the shelf over the hood by using a flexible or rigid pipe ø120 mm Fix the pipe in position using sufficient pipe clamps not supplied Fix the air outlet grid 8 on the recirculation air outlet by using the...

Page 9: ... Fixed When pressed briefly turns the Motor on at Speed three Flashing Pressed for 2 Seconds Activates Speed four with a timer set to 6 minutes after which it returns to the speed that was set previously Suitable to deal with maximum levels of cooking fumes L Light Turns the Lighting System on and off Warning Button T1 turns the motor off after first passing to speed one ...

Page 10: ...These can be washed in the dishwasher and need to be cleaned whenever the S1 Led comes on or at least once every 2 months use or more frequently if use is particularly intensive CLEANING THE FILTERS Resetting the alarm signal Turn the Lights and the Suction Motor off Press T3 and hold for at least 3 seconds until LED flashes three times in confirmation Cleaning the Filters Open the doors Remove th...

Page 11: ... Turn the Lights and the Suction Motor off Press button T2 and hold it for 5 seconds until the LED flashes twice in confirmation CHANGING Resetting the alarm signal Turn the Lights and the Suction Motor off Press T3 and hold for at least 3 seconds until LED flashes three times in confirmation Changing the Filter Open the doors Remove the Metal Grease Filter Remove the saturated Activated Charcoal ...

Page 12: ...Service www blaupunkt einbaugeraete com 1800 252 878 658 Australia CustomerCare blaupunktAU com ...

Reviews: