7
DC
9V
ON
LEARN
Door Contact
• The Door Contact should be mounted as
high as possible.
• Do not aim a PIR sensor directly at this
door/window.
• Magnet: higher (on window/door).
Sensor: Lower (on frame). Distance: max.
1,5 cm.
Control Panel
• The Control Panel should be installed in a
hidden area, preferably invisible from the
outside.
• The Control Panel requires Ethernet and
Power connections.
PIR Sensor and PIR Camera
• Mount the PIR Sensor at 1.9 - 2m height for
the best performance. When mounted at
2m height, the PIR sensor has a range of
12m.
• PIR Sensor detection is most effective if the
intruder is moving across its field of view
from the sides, at a right angle. Therefore,
do not mount PIR sensor in a location that
faces the intruder directly. It is preferable to
mount it in a corner of the room.
• Do not mount the PIR Sensor directly
exposed to sunlight, as this may affect the
detection sensitivity.
•
Do not point the PIR Sensor at windows,
moving objects or sources of heat, e. g.
fire or a boiler.
3.4 Device Location Planning