Summary of Contents for SA 2500

Page 1: ...SA 2500 Kit User Manual ...

Page 2: ...______________________10 5 Connect2Home Application____________________________________________11 6 System Information and Operation ______________________________________32 7 Troubleshooting _____________________________________________________36 8 Specifications _______________________________________________________38 Information and illustrations are subject to change within this document Blau...

Page 3: ...ed when the device is removed from mounted surface or its cover opened When the tamper switch is triggered the alarm system will be activated to inform you To make sure the tamper switch functions properly please make sure the switch is fully depressed against the mounting surface when installing your accessory devices System Extension Aside from the devices included in the package you can further...

Page 4: ...itted simutaneously from PIR and Door Contact could cancel each other Do not mount the PIR sensor directly exposed to sunlight Do not point PIR sensor at window or sources of heat e g fire or boiler Control Panel The Control Panel should be mounted in a hidden area and invisible however still accessible The Control Panel should be mounted at a location with good GSM strength to send report and rec...

Page 5: ... whether SIM Card PIN code is disabled insert the SIM card into a working mobile phone go to SIM card PIN code setting in mobile phone setting functions to disable the SIM card PIN code 3 If a prepaid SIM card is used please check the SIM card information carefully as each SIM card provider has their own policy Some SIM cards have a validity period and must be extended before they expires some SIM...

Page 6: ... times to discharge 3 Insert the new battery and replace the cover Door Contact The Door Contact detects door window opening and notifies the Control Panel to raise alarm The Door Contact is powered by a 3V lithium battery pre inserted by factory Pull out the plastic battery saver tab on the back of Door Contact This will activate the batteries Press the learn button to transmit learn code When th...

Page 7: ...u have triggered an entry Door Contact or PIR sensor The Remote Controller is powered by a CR2032 3V lithium coin cell which is included in the package Open the back battery cover to insert the battery then replace the cover When the battery voltage runs low slide open the battery cover to change new battery Arm Button Disarm Button Home Button Emergency Button Battery Cover LED Indicator ...

Page 8: ... On the Battery Switch to charge the battery and prevent accidental power shortage 3 The LEDs will light up briefly to indicate powering on LED Indicators The LED indicators represent the status of control panel 1 Power LED Green LED On AC Power connected Green LED Flash AC Power failure 2 Mode LED Red LED On The Control Panel is in Away Arm mode Red LED Flash The Control Panel is in Home Arm mode...

Page 9: ...m system Please see below for learning instruction 1 Under Disarm mode press the Function Button once the Control Panel will emit 1 beep and the Mode LED will begin to flash to indicate the Control Panel is now under Learning Mode 2 Under Learning mode press the learn test button on your accessory device to transmit a learn code Please refer to the device manual for detail 3 The Control Panel will...

Page 10: ...r tamper location Control Panel 1 Use the two holes on the Wall Mounting Plate mark the position of the holes on the wall at chest height 2 Drill two holes into the wall fix the mounting plate on the wall with screw and plugs provided 3 Hook the Control Panel onto the plate PIR Sensor The PIR Sensor has knockouts on the back where plastic is thinner The 2 center knockouts are for flat wall mountin...

Page 11: ...oor window as shown in the picture below The gap between the Door Contact and the magnet should be no more than 15 mm 2 Drill holes into the wall using the knockouts as template then fix the Door Contact base onto the wall with the screws and plugs provided Alternatively you can also use the double side adhesive tape provided to glue the Door Contact on the frame 3 Replace the Door Contact cover o...

Page 12: ...ice message upon connection or send an SMS message Address Message The Address Message will be played in the beginning of all your voice message reports to notify the recipient of your user information Please make sure you have recorded your own Address Message by referring to the previous chapter 3 Getting Started Alarm Length Default alarm length for siren upon activation is set to 3 minutes To ...

Page 13: ...tart the application The application is only compatible with iPhone or Android phone it does not support iPad or Android tablet computer System Requirement iOS 4 3 or higher for iPhone Android 2 2 or higher for Android phone IMPORTANT NOTE 1 After you send a SMS message to the Control Panel please make sure you receive a confirmation message from the Control Panel If you receive an error message o...

Page 14: ...ur panel information please select the icon Enter the panel information including the panel name you want to use in the application panel SIM card phonenumber a User PIN Code and the SMS keyword used to access the panel Press Done to confirm when finished You will return to Panel Selection menu the new panel you entered will be displayed NOTE The PIN Code and SMS Keyword entered in Panel Informati...

Page 15: ...13 Delete Panel To delete existing panel press Remove The screen will show Press the button Then press Delete the panel will be removed from the application ...

Page 16: ...dit Panel Information You can edit your control panel information by pressing Edit Enter the new panel name panel SIM card phonenumber and PIN Code and the SMS keyword you desired Press Done to confirm when finished Away Arm Home Arm Disarm To change system mode select the icon for Arm Home Disarm respectively A SMS message edit screen will appear for you to confirm Press Send to send the SMS comm...

Page 17: ...hange SMS Keyword or User PIN Code 1 and save the setting the SMS Keyword and PIN Code stored in Panel Information will also be updated accordingly Please make sure the Control Panel successfully receives the SMS command If the panel fails to receive the SMS command you need to edit the Panel Information manually to change SMS Keyword or PIN code back to previous setting Otherwise you will no long...

Page 18: ...hen a device set with entry attribute is triggered under Disarm mode Default door chime is Disable Jamming function Signal interference detection feature When RF signal jamming interference is detected for a continuous 30 seconds the alarm will be activated Factory Default is Disable High Temperature alarm Optional Temperature Sensor required When enabled if the temperature exceeds this threshold ...

Page 19: ...ol panel will send a SMS message to the number assigned to SMS reporting SMS reporting are separated into three types Alarm Status All Alarm if there is an alarm event the control panel will send the alarm information to the programmed phone number Status If there is a status change from Arm to Home Arm etc the control panel will send the status change information to the programmed phone number Al...

Page 20: ...ional Siren Device required and learn in or control Power Switch Optional Power Switch required SA2500 Control Panel does not support Capture Image function please skip this option NOTE You can delete the telephone number by keeping the telephone number field blank and save the setting ...

Page 21: ... This Device Siren Control Optional Siren required The Siren Control option allows you to change Siren settings Select the function you want to edit and choose to enable or disable the function Press Save A SMS message edit screen will appear for you to confirm Press Send to send the SMS command to panel Tamper setting The siren has built in tamper protection function to raise alarm when they are ...

Page 22: ...anel The panel will transmit signal to Repeater upon receiving the SMS command Please refer to Repeater manual for further detail PSS Control Optional Power Switch required The Power Switches can be controlled manually or through Home Automation settings to turn on off you home appliance remotely to monitor your home environments PSS Learning 1 Put the Power Switch into Learning mode Please refer ...

Page 23: ...le disable the rule 3 Select the Power Switch channel to be controlled 4 Choose to turn on or off the Power Switch 5 Select the duration of on off status 6 For High Low Temperature condition set the temperature threshold for the Power Switch to be activated deactivated 7 For Time condition set the time when the Power Switch should be activated deactivated 8 For Alarm Event condition set the events...

Page 24: ...n including the panel name you want to use in the application panel SIM card number the PIN Code and SMS keyword used to access the panel Press Save to confirm when finished You will return to Panel Selection menu the new panel you entered will be displayed Select the panel name to enter panel menu NOTE The PIN Code and SMS Keyword entered in Panel Information are included in every SMS command sen...

Page 25: ...the new panel name panel SIM card number and PIN Code and the SMS keyword you desired Press Save to confirm when finished Away Arm Home Arm Disarm To change system mode Press the Arm Home Disarm buttons The phone will send a SMS command to panel to execute the command Sync with Panel Press the Menu button on you Android phone to bring up the Sync option Press Sync to send an SMS command to Control...

Page 26: ...change SMS Keyword or User PIN Code 1 and save the setting The SMS Keyword and PIN Code stored in Panel Information will also be updated accordingly Please make sure the Control Panel successfully receives the SMS command If the panel fails to receive the SMS command you need to edit the Panel Information manually to change SMS Keyword or PIN code back to previous setting Otherwise you will no lon...

Page 27: ...o sensors will trigger the alarm and you can exit the premises before the system enters arm mode Default exit time is 30 seconds Exit sound Exit time countdown beep volume Default exit sound is Low Entry time Time period given after triggering a device set with Entry attribute During this time the system will need to be disarmed or the alarm will be activated Default Entry time is 20 seconds Entry...

Page 28: ...d choose to sync either the configurations or high low temperature setting Reporting Setting The Report Setting Menu allows you to edit your telephone numbers for reporting The SA2500 Kit can program up to 6 telephone numbers for status or alarm reporting The telephone numbers can either be voice reporting or SMS reporting Voice reporting The control panel will dial the number assigned to voice re...

Page 29: ...r 4 6 Device Setting The Device Setting Menu allows you to edit device Control Siren Optional Siren Device required and learn in or control Power Switch Optional Power Switch required Select the top column to choose between Edit Device Siren Control and PSS Control SA2500 Control Panel does not support Capture Image function please skip this option NOTE You can delete the telephone number by keepi...

Page 30: ...ther devices without attribute you can select any attribute as it will not affect the device setting Press Save The phone will send a SMS command to panel You can also remove the device specified by pressing Delete This Device You can press the Menu button on your Android phone to bring up the Sync options and choose to sync device information in different zones Device Type information will only b...

Page 31: ...or arming and disarming confirmation When set to Enabled the Siren will beep when the system is armed or disarmed to confirm the mode change When set to Disabled the Siren will not beep when system mode is changed Entry Exit Setting The Outdoor Siren and Indoor Siren can be enabled or disabled from sounding warning beeps during Entry Time and Exit Time When set to Enabled the Siren will beep durin...

Page 32: ...Switch Press Save to send the SMS command to panel Home Automation Rules Optional Power Switch required 1 With Home Automation rules you can program the Power Switches to turn on off for preset duration under different conditions This function allows you to control your home environment when away 2 The following conditions are available for settings Arm When the system is Away Armed Home When the ...

Page 33: ...the Power Switch to be activated deactivated you can set more than one events 9 Press Save The phone will send a SMS command to panel to program the Home Automation setting NOTE For system mode change Arm Home Disarm the Power Switch channel selection is limited to 1 only For High Low Temperature and Time setting You can select any Power Switch channel from 1 4 Higher Lower temperature setting in ...

Page 34: ...S command Stopping the Exit Timer You can stop the exit timer before it finishes counting down To do that you can either 1 Press the disarm key on the remote controller or 2 Select disarm on the Connect2Home application or Extending the Exit TImer You can reset the exit timer to its initial duration before it finishes counting down 1 Press and hold the Away Arm or Home Arm key on the Remote Contro...

Page 35: ... is triggered the alarm will be activated immediately 2 When a device previously set to Entry is triggered the Entry countdown timer will be activated If the system is not disarmed before the timer expires an alarm will be activated 3 When a device previously set to Home Omit is triggered in Home Arm mode the device will be ignored If the device is triggered in Away arm mode the alarm will be acti...

Page 36: ...essage It will first play the general part of the recorded message Address then plays the specific alarm message Burglar Fire Medical or Emergency depending on the nature of the alarm To ensure the call is successfully received by the recipient the recipient should acknowledge the message by pressing the appropriate button on his telephone set If the Control Panel does not receive any acknowledgem...

Page 37: ...el will redial the telephone to retry the report for a maximum of 5 times Auto Redial When only one telephone number is stored and the number is engaged the Control Panel will automatically redial up to 5 times with an interval of 80 sec between each attempt When more than one telephone numbers are stored the Control Panel will dial according to priority order If the number being dialed is engaged...

Page 38: ...s there is a fault in the GSM functions Check if SIM card is properly installed Check if SIM card s PIN is inactive Check if the signal strength is strong enough Interference Perform Walk Test on all your devices to check if Control Panel can still receive their signals Use Test Call function to test if Control Panel can report normally to programmed telephone number PIR Sensor PIR LED flashing wh...

Page 39: ...l Panel GSM signal is normal Make sure the SMS Keyword and PIN Code in the application is identical to Control Panel setting Avoid sending multiple commands in a short time Wait until receiving confirmation message from the Control Panel before sending the next command Factory Reset The Factory Reset function will delete all learned in devices and returns all system setting to default value After ...

Page 40: ...nvironment Control Panel Siren Output 96 dBA sound pressure 1m minimum Zones 30 radio devices Plus 4 optional Power Switches Power Supply 9VDC 1A Power Adaptor Battery 4 8V 600mAH Ni MH Rechargeable Battery charge time 72 hours Battery Backup Time 18 hours PIR Sensor Radio Frequency 868MHz Battery 1 x 3V lithium battery Door Contact Radio Frequency 868MHz Battery 1 x 3V 1 2 AA lithium battery Remo...

Page 41: ... 1 2012 05 FCC FCC Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution To assure continued compliance any changes or modifications not expressly approved by the pa...