PIR giving false alarm:
-- Make sure pets have no access to protected area.
-- Make sure the PIR is not pointed at source of heat or moving objects
Door Contact
Door Contact LED flashing when activated:
-- Door Contact is on low battery or tamper switch triggered.
Door Contact is not responding to door/window opening
-- Door Contact battery is exhausted, please change battery.
-- The magnet is too far away from the Door Contact; please check the gap between the magnet
and the Door Contact. Reduce the gap and test the Door Contact again.
Remote Controller
Remote Controller LED glows dimply when any key is pressed
-- Remote Controller on low battery.
Connect2Home Application
The system is not responding to SMS command
-- Make sure the Control Panel GSM signal is normal.
-- Make sure the SMS Keyword and PIN Code in the application is identical to Control Panel
setting.
-- Avoid sending multiple commands in a short time. Wait until receiving confirmation message
from the Control Panel before sending the next command.
Factory Reset
The Factory Reset function will delete all learned in devices and returns all system setting to default
value. After the setting you will need to setup the system again from the beginning via
First Time
Setup
.
1. Power down Control Panel and turn off the battery switch
2. Apply power while holding down the
Function
key.
3. All LEDs will flash for 5 times.
4. All programmed parameters are reset to factory default setting.
NOTE:
Once the
Factory Reset
is executed, all the programmed data are returned to its default
value and all the devices having been learnt-in are removed. You have to do the programming
and learn in the device one by one again.