PAGE 25
OM-9603
Revision Date: 12/15/04
Date Printed: Tuesday, February 08, 2005
CONVERSION KIT SHOULD INCLUDE REGULATOR, MAIN BURNER ORIFICE, AND PILOT ORIFICE.
Caution: Before proceeding with the conversion the gas supply must be shut off prior to disconnecting
the electrical power.
BLAZE KING RECOMMENDS THIS PROCEDURE IS DONE BY QUALIFIED SERVICE PERSONNEL.
1. ................. Remove the 2 screws holding the regulator plate on valve. Remove regulator and gasket.
Position new gasket over pins and install new regulator with notched corner up.
2 .................. Open the front access door.
3. ................. Remove embers and logs.
4. ................. Lift front of burn tray and remove through door.
5. ................. Using a 1/2” wrench, break the compression fitting loose on the pilot line.
6.................Locate the 2 screws securing the pilot assy to the bottom of the fire box. Remove screws.
7. ................. Change the main burner orifice by unthreading existing orifice from fitting with
1/2 inch wrench. Replace with an appropriate orifice. Remove pilot line by
unscrewing 1/2 inch brass fitting. Remove the pilot orifice. Replace with an
appropriate pilot orifice.
8. ................. Reverse steps 1 to 6 to complete conversion.
9 .................. Fill in the conversion label on the label plate with the conversion information and fill out the label
#0630 that came with the conversion kit and place it on the inside of the side door near the valve.
WARNING: EACH CONNECTION MUST BE INSTRUMENT CHECKED OR SOAP CHECKED FOR LEAKS
WITH GAS PRESSURE ON.
BURNER CONVERSION -ROBERT SHAW VALVE
LP OR NATURAL GAS
BURNER CONVERSION HONEYWELL VALVE
LP OR NATURAL GAS
CONVERSION KIT SHOULD INCLUDE REGULATOR SCREW, MAIN BURNER ORIFICE, AND PILOT ORIFICE.
CAUTION: Before proceeding with the conversion the gas supply must be shut off prior
to disconnection the electrical power.
1. .................Remove the grey plastic cap from the colored screw on the regulator knob. Back out colored
screw and replace with different colored screw provided in kit. NOTE: Red is LP, Blue is Natrual Gas
2 ..................Open the front access door.
3. .................Remove embers and logs.
4. .................Lift front of burn tray and remove through door.
5. .................Using a 1/2” wrench, break the compression fitting loose on the pilot line.
6................. .Locate the 2 screws securing the pilot assy to the bottom of the fire box. Remove screws.
Unthread the fitting the rest of the way, remove and replace pilot orifice
7. .................Change the main burner orifice by unthreading existing orifice from fitting with
1/2 inch wrench. Replace with an appropriate orifice.
8. .................Reverse steps 1 to 7 to complete conversion.
9 ..................Fill in the conversion label on the label plate with the conversion information and fill out the label
#0630 that came with the conversion kit and place it on the inside of the side door near the valve.
WARNING:
EACH CONNECTION MUST BE INSTRUMENT CHECKED OR SOAP
CHECKED FOR LEAKS WITH GAS PRESSURE ON.