HIGH ALTITUDE STATEMENT
This unit has been tested for installations at a high altitude (1370 meter or higher) in accordance with Canadian test standard CAN/CGA-
2.17. Higher altitudes effect their atmospheric pressure & heat value of gaseous fuels. When installing this unit at high altitudes, the
rated input will be lower than at sea level. The lowered oxygen content in the air and lowered gas density requires installing a different
orifice in order to achieve clean combustion of the unit. Consult the unit data plate for proper high altitude orifice size and fill out the
information sticker attached to the unit when field converting. For high altitude installations, consult the local gas distributor or the
authority having jurisdiction for proper rating methods.
“This conversion kit shall be installed
by a qualified service agency in
accordance with the manufacturer's
instructions and all applicable codes
and requirements of the authorities
having jurisdiction. If the information
in these instructions is not followed
exactly, a fire, explosion or production
of carbon monoxide may result
causing property damage, personal
injury or loss of life. The qualified
service agency is responsible for the
proper installation of this kit. The
installation is not proper and complete
until the operation of the converted
appliance is checked as specified in
the owner instructions supplied with
Cet èquipement de conversion sera installè
par une agence qualifièe de service
conformèment aux instructions du fabricant
et toutes exigences et codes applicables de
l`autorizès
avoir
la
juridiction.
Si
l`information dans cette Instruction n`est
pas suivie exactement, un feu, explosion
ou production de protoxyde de carbone peut
rèsulter le dommages causer de propiètè,
perte ou blessure personnelle de vie.
L`agence qualifièe de service est esponsable
de l`installation propre de cet èquipement.
L`installation n`est pas propre et complète
jusqu`à l`opèration del`appareil converti est
chèque suivant les critères ètablis dans les
instructions de propriètaire provisionnèes
avec l`èquipement.
AFTER CONVERSION IS COMPLETE TURN TO PAGE 20 OF THIS MANUAL AND