PAGE 8
OM-9603
Revision Date: 12/15/04
Date Printed: Tuesday, February 08, 2005
USE ONLY SIMPSON DURAVENT TYPE GS PIPE
USE DURAVENT TYPE GS TERMINATION CAPS
(Must obtain the modified cap from Blaze King)
UNIT IS FACTORY EQUIPPED FOR 0-610m (0-2000ft)
This appliance must be install in accordance with the manufacture’s instructions and the manufactured home construction and
safety standards, Title 24 CFR, Part 3280. This appliance must be installed in accordance with local codes if any; if not follow
the current ANSI Z223.1 or CAN/CGA-B149
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
Unit to Sidewall 11 in. (280mm) Alcove Minimum Width 47” (1190mm)
Unit to Backwall 4 in. (100mm) Alcove Minimum Height 54” (1370mm)
Unit to Adjacent Wall Corner 2 in. (50mm) Alcove Maximum Depth 30” (760mm)
Unit Top to Mantel 18 in. (450mm)
Electrical Rating: 115 Volts, 0.7 Amperes, 60HZ.
18” Floor protection required if unit is not on a 6” or higher elevated Hearth. (Insert only)
DANGER: Risk of electrical shock. Disconnect power before servicing unit. Do Not route power cord beneath heater.
Not for use with Solid Fuel.
MANUFACTURED BY: MANUFACTURE DATE:
WH-
BLAZE KING PEGASUS 9603
Listed Gas-Fired Direct Vent Room Heater
Also for installation in a Mobile Home
Certified for U.S. and Canada
Homologue Pour Le Canada
This stove is factory equipped for:
Natural Gas Propane
JAN
FEB MAR APR
MAY
JUN JUL AUG
SEP OCT NOV DEC
2005 2006 2007 2008
Tested to ANSI Z21.88b-2003 / CSA 2.33b-2003”Vented Gas Fireplace Heater”.
Acceptable for mobile (manufactured) home installations after first sale of home
This Direct Vent gas fireplace is not for use with air fillters
Direct Vent Gas Fireplace Heater - Not For Use With Soid Fuel
MODEL 9603
GAS APPLIANCE RATING
NATURAL GAS
LP GAS
TOP OUTLET REAR OUTLET TOP OUTLET REAR OUTLET
HIGH BURN STEADY STATE EFFICIENCY
81%
81%
83%
83%
INPUT RATING (BTU/HR) 0-610 m (0-2000 FT.) ALT.
38,000
36,000
38,000
36,000
ORIFICE (DMS) 0-610 m (0-2000 FT.) ALT
1/8
31
50
51
INPUT RATING (BTU/HR) 610-1370 m (2000-4500 FT.) ALT. (US) * 38,000
34,500
38,000
34,500
ORIFICE (DMS) 610-1370 m (2000-4500 FT.) ALT. (US) *
1/8
32
50
52
INPUT RATING (BTU/HR) 610-1370 m (2000-4500 FT.) ALT. (CAN)† 36,100
34,500
36,000
34,700
ORIFICE (DMS) 610-1370 m (2000-4500 FT.) ALT. (CAN)†
31
32
51
52
MANIFOLD PRESSURE (IN. W.C. / KPA)
3.5 / 0.87
3.5 / 0.87
11.0 / 2.74 11.0 / 2.74
MANIFOLD PRESSURE LO SETTING (IN. W.C. / KPA)
1.3 / 0.32
1.3 / 0.32
2.7 / 0.67
2.7 / 0.67
MINIMUM INLET PRESSURE (IN. W.C. / KPA)
4.5 / 1.12
4.5 / 1.12
12.2 / 3.04 12.2 / 3.04
MINIMUM INPUT (BTU/HR)
22,500
21,200
19,700
17,800
MINIMUM OUTPUT (BTU/HR)
17,400
16,350
15,300
13,800
MAXIMUM OUTPUTS ARE WITH FANS ON. MINIMUM OUTPUTS ARE WITH FANS OFF.
* SPECIFICATIONS USING U.S.A. HIGH ALTITUDE METHOD.
† SPECIFICATIONS USING CANADIAN HIGH ALTITUDE METHOD.
0781B
COPY OF APPROVAL LABEL
Blaze King Industries
146 A Street
Walla Walla, WA.
99362
Ph# 1-509-522-2730
Valley Comfort Systems Inc.
1290 Commercial Way
Penticton, BC
V2A 3H5
Ph# 1-250-493-7444