OM-AF30 E V1.02
October 18, 2013
Page 15
ASHFORD 30
INSTALLATION INSTRUCTIONS cont.
MOBILE HOME (AND RESIDENTIAL ALCOVE INSTALLATIONS)
A fan kit is required for these installations (See next page for kit and part numbers). Mobile home installations
also requires the Outside Air Kit: Z1726B. Th
ey are easiest to mount before the stove is installed. See
instructions packed with each kit.
When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed
precisely. You must also purchase (from the same manufacturer) and install the ceiling support package, fi re
stops (when needed), insulation shield, roof fl ashing, chimney cap, etc. Maintain the proper clearance to the
structure as recommended by the manufacturer.
Chimney connector must be double wall close clearance type with either ULC629 or ULCS610 designation.
Single wall pipe is not allowed in Mobile Homes or in Alcove Installations. Insulated chimney components
must be a listed factory built chimney suitable for use with solid fuels and conforming to, ULC629 in Canada or
UL-103HT in the USA. For Mobile home, the chimney need to be removable to allow for transportation of the
mobile home.
MOBILE HOME:
WARNING - DO NOT INSTALL IN SLEEPING ROOM
CAUTION - THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL
AND CEILING/ROOF MUST BE MAINTAINED.
In mobile home installations, the stove must be securely fastened to the fl oor using the tie-downs provided
in the Outside Air kit.
Use the Leg Anchor Kit H/Z2872 to secure stove to fl oor.
ALSO, a #8 ground wire must be attached to the stove and an appropriate ground.