OM-AF20.1 E V1.02
May 15, 2015
Page 12
AF20
.1
INSTALLATION INSTRUCTIONS cont.
MINIMUM CLEARANCES for AF20.1
G = 2 5/8” (67mm) in USA
8” (203mm) in Canada
H = 16” (406mm) in USA
18” (456mm) in Canada
I = 0” (0mm) in USA
8” (203mm) in Canada
K = 18” (456mm) for single wall pipe in Canada
Ember protection shield (not required to have an insulation value)
is to be listed under UL 1618-2009 (type 1) and must have a minimum size of:
In USA: 32” x 40 1/8” (813 x 1019 mm)
In Canada: 42 3/4” x 50 1/8” (1086 x 1273 mm)
Min. Alcove minimum width 52”, maximum depth 48”, minimum height above stove top 37”
This stove must be installed in compliance with all local codes and regulations.
Residential Installations
A
B
C
D
E
F
J
Roof exit, parallel and corner.
12.75”
324 mm
6.5”
166 mm
26.125”
664 mm
15.875”*
404 mm
6”
153 mm
18.125”*
461 mm
37”
940 mm
Wall exit, parallel and corner.
12.75”
324 mm
6.5”
166 mm
26.125”
664 mm
15.875”*
404 mm
6”
153 mm
18.125”*
461 mm
37”*
940 mm
Alcove, roof exit. Fan kit required.
12.75”
324 mm
6.5”
166 mm
26.125”
664 mm
15.875”*
404 mm
37”
940 mm
Mobile Home Installation
Roof exit, parallel and corner. Fan kit and outside air kit required.
12.75”
324 mm
6.5”
166 mm
26.125”
664 mm
15.875”*
404 mm
6”
153 mm
18.125”*
461 mm
37”
940 mm
* Check with local codes and pipe manufacturer for pipe clearances. In Canada, 18” clearances from single wall pipe is required.
Clearances may only be reduced by means approved by the regulatory authority
I
H
G
G
A
C
2"(51 mm)
D
B
*1
*1
I
H
G
G
F
E
K
J
" in USA
2
*1= 5
7
8
" in Canada and 2
1
8
" in USA
*2 = 58
1
2
" in Canada and 56
1
*2
*3ft recomended
MIN.2ft*