OM-AF20.1 E V1.02
May 15, 2015
Page 5
AF20
.1
Model
Ashford 20.1 (catalytic)
Height
30 3/8” (772 mm)
Width
26 3/4” (680 mm) (without removable bypass handle)
Depth
27 1/8” (689 mm) (without optional fan kit)
28 1/4” (718 mm) (with optional fan kit)
Flue collar
6” I.D.
Recommended fl ue draft
.05” water column (on high burn)
Fire door opening
15 5/8” x 8” (397 mm x 204 mm)
Firebox depth
16” (407 mm) brick to brick, 18 1/2” (470 mm) brick to glass
Firebox width
17 1/2” (445 mm)
Firebox height
10 3/4” (273 mm)
Firebox capacity
1.8 cu. ft.
Recommended Fuel length
16” max. (407 mm)
Wood capacity (approximate):
White oak - 45 lbs. (20.41 kg)
Fir - 30 lbs. (13.61 kg)
Construction
10 gauge & 1/4” fi rebox, brick lined
Cast iron outer shell
Shipping Weight (Firebox only)
450 lbs. (205 kg)
Chimney recommendation (Minimum)
15’ from stove top to chimney cap: Insulated liner recommended
SPECIFICATIONS
Th
is unit was tested and listed UL 1482-2011 and ULC-S627-00 by
OMNI-Test Laboratories.
Th
is manual describes the installation and operation of the Ashford
AF20.1 catalytic equipped wood heater.
Th
is heater is certifi ed to comply with the 2015 U.S. Environmental
Protection Agency’s particulate emission limits for wood heaters sold
aft er May 15, 2015.
Under specifi c test conditions this heater has been shown to deliver heat at rates ranging from 8822 to 27550 Btu/hr.
Th
is wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal regulations
to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this
manual.
Th
is wood heater contains a catalytic combustor, which needs periodic inspection and replacement for proper operation.
It is against federal regulations to operate this wood heater in a manner inconsistent with operating instructions in this
manual, or if the catalytic element is deactivated or removed.
Th
e combustor supplied with this heater is a Z0336A-M metal combustor. Consult the catalytic combustor warranty also
supplied with this wood heater. Warranty claims should be addressed to:
in Canada
in USA
Blaze King Industries / Valley Comfort Systems
Warranty Department, 1290 Commercial Way
Penticton, BC Canada V2A 3H5, Ph: 250-493-7444
Blaze King Industries
Warranty Department, 146A Street
Walla, Walla, Washington 99362, Ph: 509-522-2730
EMISSIONS
CO Average(%)
g/hr
Low Burn
0.20
0.79
Med-low Burn
0.13
1.37
Med-high Burn
0.08
1.23
High Burn
0.16
2.15