background image

Classic Wood Stoves

Princess Ultra Shown With Optional Convection Deck and

Gold Door.  Ash Pan & Side Shields As Shown Are Standard.

NOTICE: Improper installation of your wood burning appliance or failure to operate it according to the guidelines detailed in the owners manual, may negate your warranty and endanger your home or
family.  Contact local building or fire officials about restrictions and installation requirements in your area.  Photos and illustrations are for descriptive purposes only.  Changes dictated by the manufactur-
er’s continuing design improvement programs may not be shown.  These products are covered by one or more patents in the United States, Canadian and other countries.  All Blaze King

®

Industries prod-

ucts are manufactured under license agreement from:  Blaze King

®

Industries, 146 A Street, Walla Walla, WA.  99362 and in Canada by Blaze King

®

Systems Inc. 1290 Commercial Way, Penticton BC

V2A3H5. Design and specifications subject to change without notice.  Rev. 9/03 CP67195 9/02 10M

Blaze King

®

Industries

www.blazeking.com

Specifications

PEJ/PE 1006

Ultra 1006

KEJ/KE 1107

Square Ft. Heating Capacity 

1

1,500+

1,500+

2,000+

Wood Length

(Front to Back/Left To Right)

16”/20”

16”/20”

17”/23”

Wood Capacity 

(approximate)

Oak 60# 

Oak 60#

Oak 90# 

Approximate Weight

350#

410#

Width

27”

27”

30”

Depth

29”

29”

30”

Height 

(top of flue collar)

29

3/4

” 

(+4 3/4” w/legs) 

34

3/4

34” 

(+4 3/4” w/legs)

Flue Size

6”

6”

8”

Door Opening

16

3/8

” x 9” 

16

3/8

” x 9”

17

3/4

” x 10”

Minimum Floor Protection 

2

32” x 44”

32” x 44”

34” x 45”

Combustion Chamber Cu. Ft.

2.85

2.85

4.32

Min. Rear Wall Clearance 

3

6”

6”

6”

Emissions 

(Weighted Average EPA)

2.42G

2.42G

1.76G

Overall Efficiency 

82.5%

82.5%

82.5%

Low Burn Time

(Average)

20 Hours

20 Hours

40 Hours

*Figures below are for roof exit only.  Refer to Owners Manual

for other applications.

Single Wall

Mobile Home/

Standard Install  

Reduced Clearances

A.16.00”/386mm    13.00”/314mm 

PE

A.16.50”/398mm

13.50”/326mm

KE

B.26.50”/640mm    20.50”/495mm 

PE

B.27.00”/652mm

21.00”/507mm

KE

C.24.75”/598mm    16.75”/404mm 

PE

C.25.00”/603mm

17.00”/410mm

KE

D. 9.00”/217mm    6.00”/145mm

KE/PE

E. 16.00”/386mm    10.00”/241mm

KE/PE

F. 14.00”/338mm    6.00”/145mm

KE/PE

G. 2.50”/  60mm    2.50”/  60mm

PE

G. 2.00”/  48mm

2.00”/  48mm

KE

H.16.00”/386mm   16.00”/386mm

KE/PE

COMBUSTIBLE WALL

COMBUSTIBLE W

ALL

COMBUSTIBLE WALL

COMBUSTIBLE W

ALL

F

D

A

G

H

C

C

F

B

E

Floor Protection

Roof Exit*

Roof Exit*

Your Authorized Dealer:

The Facts on Btu’s:

There are only two rating methods that mean something to you, the consumer.  The first is the btu

output that is achieved during EPA testing.  This testing is quite complicated and costly milled woods are burned.  This is a stan-
dard for all manufacturer testing and is not intended to provide consumers with a model for how a stove will burn in their home.
The second method  is what Blaze King  refers to as the “Real World” method.  These btu’s are achieved during in house test-
ing using the same thing a consumer burns, split, dry cordwood.  In our tests, we use fir.  The “Real World” btu’s listed are what
the average consumer can expect to achieve, with slight variations depending upon geographical location, type of wood, eleva-
tion and amount of fuel added.  Higher Btu’s are possible.  If you were to stand in front of your stove and frequently add fuel,
burn the unit on high and have optimal conditions, the

PE1006 could produce as high as 87,850 Btu’s and the KE1107 could

exceed 90,000 btu’s!

However, maximum btu’s would only be achievable at a certain “peak” during the burn.  Blaze King does

not wish to mislead you so we give you all the facts.

PEJ/PE/Ultra 1006  

KEJ/KE 1107

Average EPA Test Fuel (Low Burn)

11,989 Btu’s/hr

8,600 Btu’s/hr

Average EPA Test Fuel (High Burn)    

35,550 Btu’s/hr   

37,800 Btu’s/hr

Average Real World Btu’s (Low Burn)

6,400 Btu’s/hr

8,400 Btu’s/hr

Average Real World Btu’s (High Burn)

40,000 Btu’s/hr  

47,000 Btu’s/hr

Classic W

ood 

Stoves

King Classic 1107 Shown With Optional Dual Fans

Common Specifications

Certified to comply with July 1990 Standards,
US (EPA) Environmental Protection Agency
1. Subject to locality, home design, home

insulation condition and fuels.

2. Any non-combustible material.
3. Requires Close Clearance /Mobile Home

Kit. See stove label or owners manual for 
specifics. Note: Princess 1006Ultra
comes standard with side shields.

For Alcove & Wall Exit Installations

refer to Owners/Operators Manual.

All Units Are EPA And Washington State Approved.