Installation Instructions
RESIDENTIAL, ROOF EXIT, STANDARD AND REDUCED CLEARANCE,
WITH PREFABRICATED CHIMNEY.
Refer to Fig. 21 and 23. Clearances from Table #1
BEFORE INSTALLATION
If the optional kits for the Jet Air fan, the Rear Shield, or the Side Shields are purchased , they are easiest to mount
before the stove is installed. See instructions packed with each kit.
When a metal prefabricated chimney is used, the manufacturer's installation instructions must be followed precisely. You
must also purchase (from the same manufacturer) and install the ceiling support package or wall pass through and "T"
section package, fire stops (when needed), insulation shield, roof flashing, chimney cap, etc. Maintain the proper
clearance to the structure as recommended by the manufacturer.
1.
Set floor protection and stove in location; refer to the clearance dimensions listed on the label and in these
instructions.
2.
Mark the position for the hole in the ceiling and roof by using a string and plumb bob.
3.
Check that the intended location will not interfere with floor joists, ceiling joists, or rafters before proceeding further.
4.
IF REQUIRED, be sure to mark the hole for Outside Air Kit.
5.
Move the stove out of the way, and if outside air is required, use a saber saw with a masonry blade and cut a 6.5”
hole for the outside air pipe.
6.
Cut a pilot hole in the ceiling.
7.
Cut a hole for the ceiling penetration components and frame in the sides of this hole in both ceiling and roof. Refer to
the pipe manufacturer's installation instructions.
8.
Install the Support Box and Chimney through roof. Install the slip section for the Chimney Connector at this time.
Refer to the pipe manufacturer's installation instructions.
9.
Following the Manufacturer’s Installation Instructions, slip the roof flashing down over the chimney and secure to the
roof, being careful to keep the pipe centered in the opening.
NOTE: To met the code, the chimney must extend above the roof at least three feet and two feet above any area
of the roof within ten feet of the termination of
the chimney. Be sure all pieces( including
outside air cap, flange, collar and pipe) are
installed at this point before putting the stove
in its final position.
10. Slide the stove back into position.
11. To install the Chimney Connector, slip the
lower (crimped) edge of the pipe inside the
smoke collar. Install the remaining lengths of
pipe, one on top of the other, to the finished
height of the Chimney Connector, and secure
to each other.
12. IF REQUIRED, install the Outside Air Flex
Pipe.
13. If the OPTIONAL, Fan Kit is installed the fan
motors are equipped with a THREE-PRONG
(grounded) plug to prevent shock hazard THIS
PLUG SHOULD BE INSERTED DIRECTLY
INTO A PROPERLY GROUNDED,THREE-
PRONGED RECEPTACLE. DO NOT CUT OR
REMOVE THE GROUNDING PRONG FROM
THIS PLUG. Do not route the power cord in
front of or under this heater.
Fig. 27 Residential Roof Edit, Prefabricated Chimney System